Brewing problems
PROBLEM
POSSIBLE CAUSE
SERVICE CHECK
SOLUTION
Display shows Tea
•
Coffee configuration
•
Check for
•
Refer to page 11 sketch
images
jumpers are not on
configuration
for information
control
jumpers
LCD display indicates
•
Brew basket is rotated
•
Check brew basket
•
Brew basket must be
“no brew basket
to left or right instead
orientation
installed straight to allow
detected” when basket
of straight in
brew basket detection
is installed
circuit to operate
Water distribution
•
Magnetic spray head is
•
Remove brew basket
•
Replace spray head if
over coffee bed is not
missing
and observe if spray
missing
uniform
head is intact
•
Spray head is dirty or
•
Remove magnetic
•
Clean or delime the spray
has mineral buildup
spray head and check
head and replace
for clogged spray
pattern holes
Filling / water leakage problems
PROBLEM
POSSIBLE CAUSE
SERVICE CHECK
SOLUTION
Water dripping from
•
Weeping water inlet
•
Check for water
•
Replace valve (non-
spray head when
valve
weeping from
serviceable item)
power is off
overflow opening on
spray dome (not
brew valve)
•
Weeping brew or
•
Observe for leakage
•
Remove brew basket and
bypass valves
at dispense valves
spray head and look for
water weeping from
brew valve outlets on
bottom of spray dome
replace valves if needed
•
Residual water in spray
•
Check spray head for
•
Clean spray head to
head
clogging
remove any coffee or
lime buildup which may
restrict the spray head
Overfilling water tank
•
Water level probe is
•
Check level probe
•
Carefully remove level
only when power is on
coated with lime
probe from retaining
grommet and remove
any deposits
•
Level probe electrical
•
Check level probe
•
Ensure level probe
connection is faulty
connections
connections are good at
the level probe, tank
ground, and control
board connections