Grifo Tele Web User Manual Download Page 7

ITALIAN TECHNOLOGY                                              

grifo

®

   Page 1

  

  Tele Web Controller          Rel. 5.00

INTRODUCTION

The use of these devices has turned - IN EXCLUSIVE WAY - to specialized personnel.
This device is not a safe component as defined in directive 98-37/CE.

Pins of Modules are not provided with any kind of ESD protection. They are connected directly to
their respective pins of microcontroller. Modules are affected by electrostatic discharges.
Personnel who handles Modules is invited to take all necessary precautions to avoid possible
damages caused by electrostatic discharges.

The purpose of this handbook is to give the necessary information to the cognizant and sure use of
the products. They are the result of a continual and systematic elaboration of data and technical tests
saved and validated from the manufacturer, related to the inside modes of certainty and quality of
the information.

The reported data are destined- IN EXCLUSIVE WAY- to specialized users, that can interact with
the devices in safety conditions for the persons, for the machine and for the enviroment, impersonating
an elementary diagnostic of breakdowns and of malfunction conditions by performing simple
functional verify operations , in the height respect of the actual safety and health norms.

The informations for the installation, the assemblage, the dismantlement, the handling, the adjustment,
the reparation and the contingent accessories, devices etc. installation are destined - and then
executable - always and in exclusive way from specialized warned and educated personnel, or
directly from the TECHNICAL AUTHORIZED ASSISTANCE, in the height respect of the
manufacturer recommendations and the actual safety and health norms.

The devices can't be used outside a box. The user must always insert the cards in a container that
rispect the actual safety normative. The protection of this container is not threshold to the only
atmospheric agents, but specially to mechanic, electric, magnetic, etc. ones.

To be on good terms with the products, is necessary guarantee legibility and conservation of the
manual, also for future references. In case of deterioration or more easily for technical updates,
consult the AUTHORIZED TECHNICAL ASSISTANCE directly.

Summary of Contents for Tele Web

Page 1: ...rifo grifo it http www grifo it http www grifo com Tel 39 051 892 052 a r FAX 39 051 893 661 GPC grifo are trade marks of grifo grifo ITALIAN TECHNOLOGY USER MANUAL Rel 5 00 Edition 27 October 2004 Te...

Page 2: ......

Page 3: ...rtedbygraphicsontheWebpage Optional WebpagetomanageaRealTimeClockbackedwithLithiumbattery Optional Web page to manage a Data Logger that can save data in Excel compatible format Optional Web page to m...

Page 4: ...s or persons resulting from technical errors omission and improper use of this manual and of the related software and hardware grifo reserves the right to change the contents and form of this document...

Page 5: ...AL FEATURES 8 ELECTRIC FEATURES 9 INSTALLATION 10 MATERIAL REQUIRED 10 POWER SUPPLY 10 SOFTWARE INSTALLATION 12 LOW LEVEL CONFIGURATION 12 ZBX MAPPING ADDRESS 15 HIGH LEVEL CONFIGURATION 16 UTILIZATIO...

Page 6: ...SNAPSHOT OF MICRO WEB SERVER 11 FIGURE 4 SNAPSHOT OF ZBR 168 11 FIGURE 5 MICRO WEB SERVER COMPLETE DELIVERY 13 FIGURE 6 LOW LEVEL CONFIGURATION 14 FIGURE 7 ZBX MAPPING ADDRESS 15 FIGURE 8 SNAPSHOT OF...

Page 7: ...onsforthepersons forthemachineandfortheenviroment impersonating an elementary diagnostic of breakdowns and of malfunction conditions by performing simple functional verify operations in the height res...

Page 8: ...msduringcardutilization itisagoodpracticetoreadcarefullyalltheinformations of this manual After this reading the user can use the general index and the alphabetical index respectly at the begining and...

Page 9: ...s Tele Web Controller so this manual describers version 1 0 of Tele Web Controller In addition this manual describes the basic version of the firmware that is the version without the several options l...

Page 10: ...ing a normal Web Browser e g Internet Explorer Netscape ecc from anywhere in the world Access to all the on board resouces through Password protected Web pages Can manage up to 32 optocoupled inputs a...

Page 11: ...TTL serial line WIDE RANGE POWER SUPPLY SECTION 2 6 20 Vdc WORKING MODE SELECTOR RUN DEBUG 1 signals protection 15 kV CPU P89LPC932 Internal MUX SPI INT ANALOG COMPARATOR PWM TIMER COUNTER PORT I O 23...

Page 12: ...ZBT This section can feature 4 8 16 or 32 latched output signals according to the model ordered Each output signal is galvanically isolated visualized through a LED and controls a not continuous 4 A...

Page 13: ...ITALIAN TECHNOLOGY grifo Page 7 Tele Web Controller Rel 5 00 FIGURE 2 PHOTO OF TELE WEB...

Page 14: ...data logger optional CPU on GPC depends on the model ordered on TWC Atmel 90S8515 Clock frequency on GPC depends on the model ordered on TWC 8 MHz PHYSICAL FEATURES Size 72 x 155 x 109 mm length of Z...

Page 15: ...ered Current consumption 5 mA GPC consumption ZBX consumption Analog inputs range optional feature depends on GPC ordered Analog inputs impedance optional feature depends on GPC ordered For further in...

Page 16: ...dule it runs the proper telecontrol firmware read the inputs sets the outputs etc ZBR ZBT this is the peripheral module featuring optocoupled inputs and relay or transistor NPN or PNP outputs in a var...

Page 17: ...ITALIAN TECHNOLOGY grifo Page 11 Tele Web Controller Rel 5 00 FIGURE 3 SNAPSHOT OF MICRO WEB SERVER FIGURE 4 SNAPSHOT OF ZBR 168...

Page 18: ...elected folder for software installation is C pwdev After unzipping to complete the installation the following commands must be typed in a DOS window or in the commands prompt C set PWDEV C PWDEV C se...

Page 19: ...ITALIAN TECHNOLOGY grifo Page 13 Tele Web Controller Rel 5 00 FIGURE 5 MICRO WEB SERVER COMPLETE DELIVERY...

Page 20: ...0 Baud 8 bit of data 1 stop bit no parity 3 Switch off supply of Tele Web 4 Enable low level configuration see next table 5 Supply Tele Web 6 From the screen that appears on terminal emulator select A...

Page 21: ...address on ABACO I O BUS is the correct one for the GPC module used For further information about ABACO I O BUS and about mapping addresses please refer to the manuals of GPC and ZBx modules used Tabl...

Page 22: ...ng the content of the file called IP in the sources folder of Tele Web Controller For example if the free IP obtained is 192 168 168 123 the command to type is SETIP 0 1 2 3 4 5 192 168 168 123 While...

Page 23: ...igure 9 type the password if present in the specific test obx or press immediatly the button if no password is set NOTE For further information about how to set the password please refer to paragraph...

Page 24: ...gif please refer to paragraph PERSONALIZATIONS To complement the status of an output it is enough to click on the corresponding icon So clicking on the icon of an output enabled this will be disabled...

Page 25: ...ITALIAN TECHNOLOGY grifo Page 19 Tele Web Controller Rel 5 00 FIGURE 10 COMMANDS PAGE OF ZBX 168 FIGURE 11 LABELS MANAGEMENT...

Page 26: ...ormed through a comfortable specific Web page available only for who orders this option and described in detail in a specific manual Shortly the above mentioned Web page allows to read and set date an...

Page 27: ...ITALIAN TECHNOLOGY grifo Page 21 Tele Web Controller Rel 5 00 FIGURE 12 CHANGE SIGNALS NAMES...

Page 28: ...is performed through a comfortable specific Web page available only for who orders this option and described in detail in a specific manual Shortly the above mentioned Web page allows to read the inpu...

Page 29: ...anages the Internet interface of the system user commands and Web response pages The compilation procedure is beyond the purposes of this manual pleare refer to Micro Web Server specific documentation...

Page 30: ...e ones you want without changing their names and to recompile the project PERSONALIZATION OF HTML PAGES Tele Web in the basic version without options uses three Web pages 1 TWCMain htm for login 2 TWC...

Page 31: ...ERTER OPTIONAL 8 ANALOG INPUTS 9 ANALOG INPUTS MANAGEMENT OPTIONAL 22 C CLOCK 8 CONNECTORS 8 CPU 8 CURRENT CONSUMPTION 9 D DARLINGTON 6 DATA LOGGER MANAGEMENT OPTIONAL 20 DATA LOGGER OPTIONAL 8 E EEPR...

Page 32: ...6 10 O OPEN COLLECTOR 6 OPTOCOUPLERS 6 OUTPUT 6 OUTPUT COMMANDS 18 P PASSWORD 12 14 17 PERSONALIZATION OF HTML PAGES 24 PERSONALIZATION OF ICONS 24 PERSONALIZATIONS 23 PNP 10 POWER SUPPLY 6 10 R RAM 8...

Page 33: ...ITALIAN TECHNOLOGY grifo Page A 3 GMB HR168 GMM AC0 Rel 5 00 T TEMPERATURE RANGE 8 TRANSISTOR 6 8 V VERSION 3 W WEIGHT 8 Z ZBR 6 10 18 ZBT 6 10 18...

Page 34: ...grifo ITALIAN TECHNOLOGY Page A 4 GMB HR168 GMM AC0 Rel 5 00...

Reviews: