Page 18
Tele Web Controller Rel. 5.00
OUTPUT COMMANDS
Entering the commands page, it is possible to control the status of transistor or relays outputs and
optocoupled inputs of ZBR/ZBT module.
Commands page is shown in figure 10, it is automatically updated every 5 seconds.
If the peripheral module installed is not ZBR/ZBT 168, you may see a different number of inputs and
outputs respect to figure 10.
Each signal features a 31 characters long label printed near the icon that shows the signal status.
When delivered, Tele-Web has all the labels set to a null string, to set them please refer to paragraph
“LABELS MANAGEMENT”.
When an output is enabled (relay contact closed or transistor conducting), this fact is indicated
painting in red its label and showing the image stored in the file called “on.gif”.
By default, the image shows the writing “ON”.
When an output is disabled (relay contact open or transistor not conducting), it is indicated showing
the image stored in the file called “off.gif”.
By default, the image shows the writing “OFF”.
To modify the images “on.gif” and “off.gif” please refer to paragraph “PERSONALIZATIONS”.
To complement the status of an output, it is enough to click on the corresponding icon.
So, clicking on the icon of an output enabled, this will be disabled, and viceversa.
INPUT COMMANDS
Entering the commands page, it is possible to control the status of transistor or relays outputs and
optocoupled inputs of ZBR/ZBT module.
Commands page is shown in figure 10, it is automatically updated every 5 seconds.
If the peripheral module installed is not ZBR/ZBT 168, you may see a different number of inputs and
outputs respect to figure 10.
Each signal features a 31 characters long label printed near the icon that shows the signal status.
When delivered, Tele-Web has all the labels set to a null string, to set them please refer to paragraph
“LABELS MANAGEMENT”.
When an optocoupled input is enabled (contact closed), this fact is indicated painting in green or
yellow (whether the bit belongs to a high byte or not) its label and showing the image stored in the
file called “on.gif”.
By default, the image shows the writing “ON”.
When an input is disabled (contact open), it is indicated showing the image stored in the file called
“off.gif”.
By default, the image shows the writing “OFF”.
To modify the images “on.gif” and “off.gif” please refer to paragraph “PERSONALIZATIONS”.
Summary of Contents for Tele Web
Page 2: ......
Page 13: ...ITALIAN TECHNOLOGY grifo Page 7 Tele Web Controller Rel 5 00 FIGURE 2 PHOTO OF TELE WEB...
Page 27: ...ITALIAN TECHNOLOGY grifo Page 21 Tele Web Controller Rel 5 00 FIGURE 12 CHANGE SIGNALS NAMES...
Page 34: ...grifo ITALIAN TECHNOLOGY Page A 4 GMB HR168 GMM AC0 Rel 5 00...