![Grifo MP AVR-51 User Manual Download Page 63](http://html1.mh-extra.com/html/grifo/mp-avr-51/mp-avr-51_user-manual_2264998063.webp)
ITALIAN TECHNOLOGY
grifo
®
Page 53
MP AVR-51 Rel. 3.10
Name
Shortcut
Function
Verify
<F8>
This command compares the programmed data of the all device
or its part with data in buffer. The control program reports a
result of this action by a sound signal and by a write of an error
message to INFO window. The menu command Device\options
allows to set another working area as the standard. By the setting
in the menu Options\Display errors the command lets You write
the found errors on the display and also it lets You print the
listing, or write the found errors to file PG4UCOMP.ERR. On
the screen can be displaied at most the first 45 differences, which
are located by the address where they were caused.
Program
<F9>
This command allows to program the whole device or only a part
of it by the data of the buffer. The control program reports a
result of this action by a sound signal and by writing a message
in the INFO window. The menu command Device\options
allows to set another working area as the standard, and set other
operation options for programming process control.
Erase
This command allows to erase the all programmable device. The
program reports the end without error or end with the error by a
sound signal and writing the warning report on the display.
Test
This command is used for select a new type of programmer. Also
is possible to select a LPT port, which will scanned for a
requested programmer. If a special port was selected, then is
recommended to set an address of this port. After a parameters
of finding was setted, scanning for a new programmer will
initiated by the command Find programmer. This setting is
saved to file PG4U.CFG by command Options\Save options.
Device Info
<Ctrl+F1>
The command provides additional information about the current
device (including auxiliary modules),which support this device.
You can find here a package information and other general
information about current device too.
Device List
This command makes a list of all devices supported by current
programmer and saves its to PROGLIST.DEV text file in the
current directory on the disk.
Summary of Contents for MP AVR-51
Page 2: ......
Page 15: ...ITALIAN TECHNOLOGY grifo Pagina 5 MP AVR 51 Rel 3 10 FIGURA 1 CONTENUTO DELLA CONFEZIONE...
Page 17: ...ITALIAN TECHNOLOGY grifo Pagina 7 MP AVR 51 Rel 3 10 FIGURA 2 FOTO...
Page 49: ...ITALIAN TECHNOLOGY grifo Page 39 MP AVR 51 Rel 3 10 FIGURE 1 PACKAGE INCLUDED...
Page 51: ...ITALIAN TECHNOLOGY grifo Page 41 MP AVR 51 Rel 3 10 FIGURE 2 PHOTO...
Page 78: ...grifo ITALIAN TECHNOLOGY Page 68 MP AVR 51 Rel 3 10 Z ZIF 38 ZIF SOCKET 36...