3.7.15 Send Characters
You can enter up to two characters in hexadecimal representation in the parameters "sendchar." If a
character received on the serial line matches one of these characters, it is sent immediately, along with any
awaiting characters, to the TCP connection. This minimizes the response time for specific protocol
characters on the serial line (for example, ETX, EOT, etc.). Setting the first sendchar to
00
disables the
recognition of the characters. Alternatively, the two characters can be interpreted as a sequence.
3.7.16 Telnet Terminal Type
This parameter appears only if the terminal type option is enabled in Disconnect Mode. If this option is
enabled, you can use the terminal name for the Telnet terminal type. Enter only one name.
If the terminal type option is enabled, the unit also reacts to the EOR (end of record) and binary options,
which can be used for applications like terminal emulation to IBM hosts.
3.7.17 Channel (Port) Password
This parameter appears only if the channel (port) password option is enabled in Disconnect Mode. If the
option is enabled, you can set a password on the serial port.
3.8 E-mail Settings
Note: Part of the NeET485 design is the option of using three I/O pins for different purposes. These are
referred to as Configurable Pins and are designated CP1, CP2, and CP3 in the Web Manager.
In order to use the E-mail function on the XPort, you will need access to the configurable pins. The NET485
limits the access so you cannot use the configurable pins to trigger an E-mail message. Your only option is
to use a two-byte serial string to initiate a trigger.
If your device sends out a lot of character strings, then it might not be a good choice to use with the E-mail
trigger option.
Note: You can change these settings via Telnet or serial connections only, not on the Web-Manager. To configure e-
mail settings via DeviceInstaller, see E-mail Notification in the DeviceInstaller User Guide.
***************** E-mail *****************
Mail server (0.0.0.0) (000) .(000) .(000) .(000)
Unit name ():
Domain name ():
Recipient 1 ():
Recipient 2 ():
- Trigger 1
Enable serial trigger input (N) ?
Trigger input1 [A/I/X] (X) ?
Trigger input2 [A/I/X] (X) ?
Trigger input3 [A/I/X] (X) ?
Message ():
Priority (L):
Min. notification interval (1 s):
Re-notification interval (0 s):
Summary of Contents for NET485
Page 1: ...NET485 RS422 485 Serial to Ethernet Adapter Revision E October 14 2013 ...
Page 2: ......
Page 16: ......
Page 54: ......
Page 56: ......
Page 60: ...Tables 7 2 NET485 User Guide Click Hex The hexadecimal value displays ...
Page 62: ...Tables 8 2 NET485 User Guide 8 1 Certificate of Compliance ...