Optional PZ12
Maximum Range:
12 ft (3.66 m)
Minimum Range (Deadband):
8" (203.2 mm)
Operating Frequency:
92 KHz
Beam Angle:
8°
Operating Temperature:
-40° to 150° (-40° to 65°C)
Temperature Compensation:
Automatic, continuous
Max. Operating Pressure:
20 psi (1.35 bar)
Sensor Face:
PVC
Sensor Body:
PVC
Mounting:
¾" NPT
Cable Length:
25 ft. (7.6 m) continuous
RG62AU coaxial. Optional
50 ft. (15 m) continuous
Max. Cable Length:
500 ft. (152 m) RG62AU
coaxial (splice)
Hazardous Rating:
CSA rated Intrinsically Safe
Class I, Groups C,D, Class
II, Groups E,F,G with
Optional Intrinsic Safety Barrier.
Optional PZ12T_F
Maximum Range:
12 ft (3.66 m)
Minimum Range (Deadband):
8"(203.2 mm)
Operating Frequency:
92 KHz
Beam Angle:
8°
Operating Temperature:
-40° to 150° (-40° to 65°C)
Temperature Compensation:
Automatic, continuous
Max. Operating Pressure:
20 psi (1.35 bar)
Sensor Face:
Teflon
Sensor Body:
PVC
Mounting:
¾" NPT
Cable Length:
25 ft. (7.6 m) continuous RG62AU coaxial. Optional 50 ft. (15 m)
continuous
Max. Cable Length:
500 ft. (152 m) RG62AU coaxial (splice)
Hazardous Rating:
CSA rated Intrinsically Safe Class I, Groups C,D, Class II, Groups E,F,G
with optional Intrinsic Safety Barrier.
Page 50
SLT32 Level & Flow Monitor
Manual Series B.11
25 ft (7.6 m) RG62AU
COAXIAL CABLE
(50 ft 15 m OPTIONAL)
3/4“ NPT
ISOLATION
COUPLING
(SUPPLIED)
3/4" NPT
1"
(25.4 mm)
~ 3.9"
(99 mm)
OVERALL
2.75"
70 mm
2.75" (70 mm)
~ 4.5"
(114 mm)
OVERALL
3.25"
82.5 mm
25 ft (7.6 m) RG62AU
COAXIAL
(50 ft 15 m OPTIONAL)
CABLE
3/4“ NPT
3/4¾" NPT
1"
(25.4 mm)
BOLT CIRCLE DIAMETER
TEFLON FACE 0.01" / 0.25mm
FLANGE DIAMETER
ISOLATION
COUPLING
(SUPPLIED)