OPTIONAL PIPE BAND MOUNTING WITH QZ02L SENSOR
Install the stainless steel pipe band with the sensor
mounting bracket at the invert (bottom) of the pipe. Ensure
that the sensor bracket is parallel to the water surface
(check with a level). Mount so the tapered end of the
sensor will point upstream and the sensor cable will point
downstream. (Turn the ¼” hex nut clockwise to expand the
bracket and secure to the pipe wall by friction fit.)
Insert the sensor into the mounting bracket and clip or tie wrap the sensor cable securely to the stainless
steel pipe band as illustrated.
OPTIONAL QZ02L-DP VELOCITY SENSOR MOUNTING
Mount the velocity sensor at the bottom of the channel or pipe in a position where it will be
continuously submerged. The QZ02L-DP velocity sensor does not have to be exactly parallel to the
water surface. Position where silt or solids will not build-up on the sensor.
Page 19
AVFM-II Area-Velocity Flow Meter
Manual Series A.10
DETAIL
BAND ADJUSTMENT
JACK
VSJ PIPE MOUNTING BAND
BAND
ADJUSTMENT JACK
SENSOR MOUNTING
BRACKET