E30.0.0X.6C-11 

Operating Manual GRA0420VO / GRA010VO 

page 3 of 12  

2   Safety regulations 

This device was designed and tested considering the Safety regulations for electronic measuring devices. 
Faultless operation and reliability in operation of the measuring device can only be assured if the General 
Safety Measures and the devices specific safety regulation mentioned in this users manual are considered. 
1.  Faultless operation and reliability in operation of the measuring device can only be assured if the device 

is used within the climatic conditions specified in the chapter “Specifications“. 

2.  Always disconnect the device from its supply before opening it. Take care that nobody can touch any of 

the unit„s contacts after installing the device. 

3.  Standard regulations for operation and safety for electrical, light and heavy current equipment have to be 

observed, with particular attention paid to the national safety regulations (e.g. VDE 0100). 

4.  When connecting the device to other devices (e.g. the PC) the interconnection has to be designed most 

thoroughly, as internal connections in third-party devices (e.g. connection of ground with protective earth) 
may lead to undesired voltage potentials. 

5.  The device must be switched off and must be marked against using again, in case of obvious malfunc-

tions of the device which are e.g.: 
-  visible damage 
-  no prescripted working of the device 
-  storing the device under inappropriate conditions for longer time 

 

When not sure, the device should be sent to the manufacturer for repairing or servicing. 

Attention:

 When running electric devices, parts of them will always be electrically live. 

Unless the warnings are observed serious personal injuries or damage to property 
may result. Skilled personnel only should be allowed to work with this device. For trou-
ble-free and safe operation of the device please ensure professional transport, stor-
age, installation and connection as well as proper operation and maintenance. 

Skilled personnel 

are persons familiar with installation, connection, commissioning and operation of the product and have pro-
fessional qualification relating to their job. 

For example: 

 

•  Training or instruction resp. qualifications to switch on or off, isolate, ground and mark electric circuits and 

devices or systems. 

 

•  Training or instruction according to the state. 

 

•  First-aid training. 

 

  

ATTENTION:

 

Do NOT use this product as safety or emergency stopping device, or in any other applica-
tion where failure of the product could result in personal injury or material damage. 

Failure to comply with these instructions could result in death or serious injury and mate-
rial damage. 

Summary of Contents for GRA 010 VO

Page 1: ...page 1 of 12 Manual for connection and operating of GRA 0420 VO GRA 010 VO as of version 1 2 GREISINGER electronic GmbH D 93128 Regenstauf Hans Sachs Stra e 26 Tel 0049 9402 9383 0 Fax 0049 9402 9383...

Page 2: ...TMENT 10 7 MIN MAX VALUE STORAGE 10 8 ERROR CODES 11 9 SPECIFICATION 12 10 DISPOSAL INSTRUCTIONS 12 1 Introduction The GRA0420VO and GRA010VO is a microprocessor controlled displaying monitoring and c...

Page 3: ...st be switched off and must be marked against using again in case of obvious malfunc tions of the device which are e g visible damage no prescripted working of the device storing the device under inap...

Page 4: ...ter is not as signed to contact 2 and if the Ub line is not assigned to contact 1 please do not forget to adjust the GRA angle type plug and the external angle type plug ac cordingly To do so open the...

Page 5: ...tation needed because of the high turn on current of high capacitive loads The same applies to incandescent lamps whose turn on current is also quite high due to their low cold resistance 3 2 1 GRA042...

Page 6: ...when a 20mA resp 10V input signal is attached Validate the selected value by pressing button 1 The display shows di Hi again Press button 1 again The display will show Li Limit Measuring range limit...

Page 7: ...ding on this setting therefore it is possible that more than one point are present in the following When pressing button 1 again the device will display 1 dEL delay delay of switching function Use but...

Page 8: ...troller AL min max alarm inverse 5 2 5 1 2 point controller This chapter describes how to configure the switching points as use the device for a 2 point controller This instruction demands that you se...

Page 9: ...on 2 and button 3 to set the desired delay of the alarm function Note the selected value 0 9999 accords the alarm delay in seconds The device will turn on the alarm after minimum or maximum alarm valu...

Page 10: ...slope adjustment The slope adjustment will be entered in The value displayed can be calculated like this Display measured value offset di Lo 1 slope adjustment 100 di Lo Example The setting is 2 00 th...

Page 11: ...signal Err 3 Display range has been exceeded Indicates that the valid display range 9999 digit of the device has been exceeded Possible causes Incorrect scale Remedies The error message will be reset...

Page 12: ...is not short circuits protected Reaction time 20 ms Connection output via angle type plug Nominal temperature 25 C Working temperature 25 50 C Relative humidity 0 80 non condensing Storage temperature...

Reviews: