background image

H63.0.11.6C-01 

Operating Manual BaleCheck 100 

page 5 of 10 

 

 

_____________________________________________________ 

_____________________________________________________________________________ 

 

4  Handling 

4.1  Display elements 

 

1: Main display 

Display of the current moisture or water 
content 

2: Material display 

The name of the selected material char-
acteristic curve is displayed 

3: Moisture display 

Moisture rating via bar graph:  

4: HLD 

The measuring value is ‘frozen‘  
(hold-key) 

4.2  Control elements 

 

Key 1: 

Ein on/off key,   

Press long: 

switch device off 

Press shortly: changeover between measuring display 

and temperature adjustment 

Key 2: 

sort  

Selection of characteristic curve:  

p.r.t. chapter 4.4 

 

Key 3: 

hold: 

press shortly: 

The measuring current value is ‚frozen‘   

                       ('HLD' is displayed) 

4.3  Start of operation 

Switch the device on with the key 

 . 

After segment test 

 the device displays some information to its configuration: 

P.OF

   if the automatic-off-function is activated (

p.r.t. chapter0

) 

The device is ready for measuring afterwards. 

4.4  Selection of the characteristic curve 

Selection of characteristic curve:  by pressing 

 the next characteristic curve will be selected. 

 The use of inappropriate characteristics can cause faulty measurements! 
 

 

Selectable material characteristics: 

Display 

Characteristic curve 

R E F

 

Reference characteristic 

X E U

 

Hay 

S T R

 

Straw 

GE T

 

Grain (wheat, barley, rye) 

 

 

 

 

Summary of Contents for BaleCheck 100

Page 1: ...H63 0 11 6C 01 GREISINGER electronic GmbH as of version 1 0 BaleCheck 100 Operating Manual Hay and straw humidity measuring device WEEE Reg Nr DE 93889386...

Page 2: ...SSAGES 8 8 RESHIPMENT AND DISPOSAL 9 9 SPECIFICATION 9 1 General Note Read this document carefully and get used to the operation of the device before you use it Keep this document within easy reach ne...

Page 3: ...guidelines This device has been designed and tested in accordance with the safety regulations for electronic devices However its trouble free operation and reliability cannot be guaranteed unless the...

Page 4: ...100 Measuring probe GSF 40 9V battery Operating Manual Protection bag ST KR 3 2 Operation and maintenance advice a Battery operation If bAt is shown in the lower display the battery has been used up...

Page 5: ...uring display and temperature adjustment Key 2 sort Selection of characteristic curve p r t chapter 4 4 Key 3 hold press shortly The measuring current value is frozen HLD is displayed 4 3 Start of ope...

Page 6: ...mass water mass of the water contained in the sample mass dry mass of the oven dried sample after water has been evaporated Example 1 kg wet hay that contains 500 g water has a moisture u of 100 Wate...

Page 7: ...o gather fast and comfortably many measurements spread over the bale store deep inside at the floor at critical weathered places in practical use this often is much more valuable than single precision...

Page 8: ...actory setting u u Measuring value displayed in moisture u w Measuring value displayed in water content w Display unit of temperature input factory setting C Temperature input in C F Temperature input...

Page 9: ...ment Measuring ranges 0 0 50 w water content 0 0 100 u material moisture Resolution 0 1 over 19 9 1 for u and w Moisture rating 6 stage bar graph display from WET to DRY Accuracy the achievable accura...

Page 10: ...H63 0 11 6C 01 Operating Manual BaleCheck 100 page 10 of 10 _____________________________________________________ _____________________________________________________________________________...

Reviews: