background image

page  6

B 600 - SYSTEM CONFIGURATION

1.1   The following parameters can be set in your   (B 600)

a. Your prefered language

:

English ,  Dutch , French ,  Italian , German

p

g

g

g

b. Your Name and Adress

:  for printout together with results.

c. Printer type    

:  EPSON (FX 80 ) or compatible  or,  HP PCL or compatible

d. Date & Time

:    Set the actual date and time of your country.

e. Your prefered presettings after switching on the B 600.

For example :  Watch type, measuring time, automatic or fixed beat selection, etc.

1.2 How to display the Configuration screen ? (picture 10)

F  U  N  C  T  I  O  N        S  E  L  E  C  T  I  O  N

1.2   How to display  the Configuration screen ?  (picture 10)

a. Switch on the B 600 .

Wait until the main menu is displayed.

b. Press - PRINT-

The following  MENU  is displayed in one of the 5 languages. 

picture 10

FREEZE =>  SET  LOGO & LANGUAGE
NEXT

=> SET TIME & DATE

BACK

=> DEFAULT ALL PARAMS

MENU+ => LOAD SAVED PARAMS
MENU-

=> SAVE ACTUAL PARAMS

PRINT

=> RETURN W/O CHANGES

WAITING FOR YOUR SELECTION .  .  .

1.3    Change the language

a. Execute step 1.2
b. Press   - FREEZE

The corresponding Menu is displayed.

c. Press   - BACK  /  BACK /

The language field  is  active.

d. Press   - MENU +

press it until the desired language appears.

e. Press   - PRINT /  PRINT /  MENU - The selection will be stored.

From this moment, the   B 600  works with the selected language.

1.4   Enter your Name and Adress 

a. Execute step 1.2
b. Press   - FREEZE

The curser stays on the left side of the 2. line.

c. Press   - NEXT   ......

Until the curser stays on the position for the 1. sign.

d. Press   - MENU + or MENU -

Until the desired sign appears.

P

NEXT

U il h

h

i i

f

h 2

i

Operating - Manual B 600 M / Q

e. Press    - NEXT   ......

Until the curser stays on the position for the 2. sign.

f.  Press   - MENU + or MENU -

Until the desired sign appears.

g. Go on this way until the text looks as you wish. 
h. Press   - PRINT /  PRINT /  MENU - The selection will be stored.

Summary of Contents for B 600 M

Page 1: ...ervibrograf ch www greinervibrograf ch Vibrograf B 600 M Q Vibrograf B 600 M Q User manual User manual User manual User manual Operating Manual B 600 M Q Helmut Klein GmbH Fritz Neuert Strasse 31 7518...

Page 2: ...e 4 page 5 page 6 page 7 EXPLANATION OF TEST PARAMETERS DISPLAY OF WATCH SIGNAL AUTO CALCULATION OF AMPLITUDE MEASURING WINDOW page 7 page 8 page 9 page 10 TESTING CLOCKS TESTING QUARTZ WATCHES TESTIN...

Page 3: ...NFIXED 21600 MT 2 LA 52 26 s d 218 0 2ms On Off switch and volume adjust for internal speaker out of beat value Amplitude value time deviation sign T l b l Rear view Speaker parallel interface female...

Page 4: ...or printout 2 Switches to the double beat 1 Starts the printout 2 Switches to the single Goas to the next MENU point On Off switch and volume adjust for internal speaker Di l 2 Switches to the single...

Page 5: ...tts the watch sound noise to the cristal inside the microphone The cristal converts the noise in electrical signals Through the built in electronic and the cable the signals reaches the B 600 The sign...

Page 6: ...LANGUAGE NEXT SET TIME DATE BACK DEFAULT ALL PARAMS MENU LOAD SAVED PARAMS MENU SAVE ACTUAL PARAMS PRINT RETURN W O CHANGES WAITING FOR YOUR SELECTION 1 3 Change the language a Execute step 1 2 b Pres...

Page 7: ...NU The selection will be stored 1 6 Set the desired test parameters a Switch on the B 600 and wait until the screen 1 is displayed B 600 M WATCHTYPE PENDULUM MECHANIC 1 7 S t th d i d t t t 1 SELECT A...

Page 8: ...4 sec LIFT ANGLE MS WINDOW 100 The value of lift angle depends on the construction of the watch It is used in the B 600 to calculate the amplitude Most watches have a lift angle of 50 52 It can be se...

Page 9: ...PE PENDULUM MECHANIC In this menu press FREEZE press START STOP to return to the main menu DIAGRAM DOUBLE BEAT PRESS START STOP KEY TO COMPLETE For more ditails DIAGRAM SINGLE BEAT press PRINT to disp...

Page 10: ...plitude 230 t 0 009 s Amplitude 230 Remark The value of the time t depends on the mechanical datas of escapment from the watch This value is always measured by the B 600 and the amplitude is calculate...

Page 11: ...t always identically The B 600 may display a rong Amplitude e g 170 instead of 250 In this case you have the possibility to change the value called MS WINDOW t figure 5 The value MS WINDOW is the mini...

Page 12: ...place the light barrier max 5 mm from the arm pendulum Light barrier the arm pendulum b Switch the B 600 to PENDULUM pressing MENU B 600 M WATCHTYPE max 5 mm SELECT ACTUAL RUN PARAMETERS MECHANIC PEN...

Page 13: ...ches The shown right side is equipped with 3 capture systems red point capacitif LCD quartz 4 19MHz metal pin microphone for quartz 32 KHz yellow point inductif capture of motor impulses yellow point...

Page 14: ...watch on the yellow point Each motor impulse will be displayed with A arrow in the lower part of the display For example quartz watches with 1 second impulses Or quartz watches with inhibition of 10 s...

Page 15: ...2 5 10 20 50 100 200 500 Same watch 0 12 s d The higher you set the DSP Y GAIN value The higher is the resolution of the displayed grafic The higher is the resolution of the displayed grafic B 600 Q 2...

Page 16: ...impression that the watch signal is too weak and the grafic gives problems How to adjust Turn the Knob Level in front of the B600 in the position one o clock point to point Lay a good working watch c...

Page 17: ...ot active paralell printer connector Display 1 LCD Display adjustment of brightness with potentiometer on the rear Functional sequence 2 LED s printing and measuring Measuring possibilities mecanical...

Reviews: