  5. OPERATING YOUR WALL CONTROLS 

(CONTINUED)

Adjusting your RD Series 

Humidity Sensor Dial should be 

set accordingly or relative to the 

outside conditions. During winter 

season the Humidity Sensor Dial 

should be set within the comfort 

zone range (60% COMFORT ZONE 

30%). If the home has excess 

dryness, adjust the Humidity 

Sensor Dial towards the higher 

settings. (Turn counter clockwise). 

If excess humidity is encounter 

turn the Humidity Sensor Dial to 

a lower setting. (Turn clockwise). 

Determining the humidity level 

in your home (turn the round 

humidity sensor dial counter 

clockwise to the OFF position, 

then turn it back clockwise slowly 

until you hear “click”. The click is 

the approximate level of relative 

humidity.

NOTE: 

The comfort zone for 

relative humidity is between 60% 

and 30%; please adjust accordingly 

to your needs or requirements.

RD-1 MODEL

TM

DEHUMIDISTAT

FEATURES

• Dehumidistat to select the humidity level

Comes complete with Relative Humidity Sensor Dial.

RELATIVE HUMIDITY SENSOR DIAL  

(OFF/60%/COMFORT ZONE/30%):

• Overrides the ventilation system to high speed 

once the level of humidity is above the set point.

• If the ventilation system is in CONT or INTERM 

mode the ventilation system will automatically 

return to its original mode once the level of 

humidity is below the set point.

 

NOTE:

 By turning the relative humidity Sensor Dial 

to the OFF position does not turn off the ventilation 

system. It only deactivates the relative humidity 

sensor.

RD-2 MODEL

TM

DEHUMIDISTAT

FEATURES

• Dehumidistat to select the humidity level
• Range Control (OFF, NORMAL and REDUCED)
• Green LED light on = OVERRIDE
• Orange LED light on = CONT/INTERM

Comes complete with Relative Humidity Sensor Dial 

and Speed Control Selector Switch.

RELATIVE HUMIDITY SENSOR DIAL  

(OFF / 60% / COMFORT ZONE / 30%):

• Overrides the ventilation system to high speed 

once the level of humidity is above the set point.

• If the ventilation system is in CONT or INTERM 

mode the ventilation system will automatically 

return to its original mode once the level of 

humidity is below the set point.

 

NOTE:

 By turning the relative humidity Sensor Dial 

to the OFF position does not turn off the ventilation 

system. It only deactivates the relative humidity sensor.

RANGE SELECTOR SWITCH (OFF/NORMAL/REDUCED):

• 

OFF

 – Sends command to turn off the ventilation system.

• 

NORMAL

 – The ventilation system operates  

on installers set speeds (CONTINUOUS 

VENTILATION MODE).

• 

REDUCE

 – The ventilation system operates at 30% 

reduction in CONT and 15% in OVERRIDE set speed.

  NOTE:

 REDUCE mode will not decrease below the 

maximum low speed of the ventilation system.

Installation of a RD-Series main wall control with your HRV/ERV will improve 

comfort and may significantly reduce the product’s energy use.

Summary of Contents for C3.14 HRV

Page 1: ...MODEL PE 7 15 PE 10 22 SS 3 80 Product of Greentek Greentek reserves the rights to modify a product without prior notice whether in price design color or codes in order to offer at all times quality products that are highly competitive Greentek 50 Kanalflakt Way Bouctouche NB E4S 3M5 1 888 724 5211 Fax 1 866 426 7430 www Greentek ca Item 463674 SEPT2018 ...

Page 2: ...ons 3 3 Description of your Ventilation System 4 4 Operation of the DuotrolTM System 5 5 Operation of your Wall Controls 6 11 6 Troubleshooting 12 7 Maintenance 12 8 Warranty 13 Before servicing or cleaning the HRV system always remove the power cord from the AC wall outlet To reduce the hazards of electric shock or fire do not perform any service to the HRV system other than those stated in the o...

Page 3: ...m the heat from the outgoing stale air and use this heat to temper the incoming fresh air which reduces the cost of effectively ventilating your home during winter NOTE Reverse process occurs in the summer months Fresh air Exhaust air Bathroom Control Forced air system HRV ERV Exhaust air hood Fresh air supply hood Exhaust and supply in the return Bathroom Control Forced air system HRV ERV Exhaust...

Page 4: ...nected to the drain pan and serves as drainage for the accumulation of water It is normal during summer months to find no condensation in drain pan or in drainage hose Automatic Defrost Sequence The defrost sequence is electronically controlled to measure the incoming outdoor air temperature the sequence is activated at 5 C 23 F and colder This system eliminates that the heat recovery or energy re...

Page 5: ...h speed until the level of humidity is below the set point The T 3 timer has completed its time period or once the cycles per hour has completed its cycle TIP During hot and humid days it is recommended that you put the system on INTERM mode This will reduce the amount of warm and humid fresh air coming inside the house NOTE The following controls EHC1 0 EHC1 5 RD 2 RD 3P RD 3D RD 4P RD 4D will ov...

Page 6: ...tion system will increase to high speed when a auxiliary control has been activated if installed Recommended for best indoor air quality ECO Friendly continuous ventilation energy savings mode The ventilation system operates at reduced rate of 30 in continuous and at a reduced rate of 15 during maximum ventilation speed RECIRC Recirculation ventilation mode The recirculation mode recycles already ...

Page 7: ...l of humidity is below the set point NOTE By turning the relative humidity Sensor Dial to the OFF position does not turn off the ventilation system It only deactivates the relative humidity sensor RD 2 MODELTM DEHUMIDISTAT FEATURES Dehumidistat to select the humidity level Range Control OFF NORMAL and REDUCED Green LED light on OVERRIDE Orange LED light on CONT INTERM Comes complete with Relative ...

Page 8: ...eated ambient air from a selected area and distributes throughout your home This enables the ventilation system to have an auxiliary air supply automatically during defrost sequence or when RECIRC mode is selected RD 3P MODELTM DEHUMIDISTAT PROFESSIONAL FEATURES Dehumidistat to select the humidity level Range Control OFF NORMAL and REDUCED Mode Control INTERM and CONT Green LED light on OVERRIDE O...

Page 9: ... SWITCH INTERM CONT INTERM When the selector switch is in the INTER position the ventilation system will only run on high speed when there is a request for ventilation At this time the unit will run on high speed until the level of humidity is below the set point The T 3 timer has completed its time period or once the cycles per hour has completed its cycle CONT Provides continuous ventilation The...

Page 10: ...er has completed its time period or once the cycles per hour has completed its cycle CONT Provides continuous ventilation The ventilation system will increase to high when there is a request from one of the wall controls Recommended for maximum indoor air quality RECIRC The recirculation mode recycles already heated ambient air from a selected area and distributes throughout your home This enables...

Page 11: ...ess button once this will deactivate T 3 push button time and your ventilation system will return to previous settings TIPS The T 3 model push button timer allows the homeowner control of the indoor humidity level in room were excess humidity is produced Ex Bathroom kitchen laundry room TIPS Always leave a small gap when closing curtains and blinds in the winter months this will allow proper circu...

Page 12: ...aged 7 Arrange for an annual servicing Your HRV ERV should undergo annual general servicing by a certified contractor and who is familiar with your HRV If possible have your furnace and HRV serviced at the same time this will result in less inconvenience and cost than two separate visits QUESTION ITEM DIAGNOSIS SOLUTION HRV ERV not running Verify breaker in main electrical panel Verify the HRV or ...

Page 13: ... Years PH7 15 PH7 15ES XPH1 5 PE7 15 PH10 22 PH10 22ES XPX2 0 PE10 22 XDH7 15 C3 14HRV SS3 80 HRV SS3 80ERV 2 Years RNC12 RNC1 0 RNC1 5 RNC2 0 RNC2 0ES LIMITED WARRANTY ON VENTILATION MOTORS Greentek warrants the ventilation motors against defects in material and workmanship within the models warranty period from the date of original installation Greentek will provide a new or remanufactured part ...

Page 14: ...50 Kanalflakt Way Bouctouche NB E4S 3M5 1 888 724 5211 Fax 1 866 426 7430 www greentek ca Item 463674 ...

Reviews: