10 - OPERATING INSTRUCTIONS
P14
Max DHW power setting
100
100
100
100
P15
Min CH power setting
0
0
0
0
P16
Maximum Central Heating setpoint (°C)
00= 176° F (80°C)
01= 113°F (45°C)
0
0
0
0
P17
Pump overrun time in heating mode (min)
3
3
3
3
P18
Maximum overrun time before a new relight of burner in heating mode
(min)
3
3
3
3
P19
Manufacturer information. Shall be set to 7. Ignore all other options.
7
7
7
7
P20
Pump overrun time in DHW Mode (0…255 seconds)
30
30
30
30
P21
Anti-legionella function setpoint setting
00= disabled
60...67 = enabled (setpoint value °C)
0
0
0
0
P22
Set at “22” to display and edit parameters from P42 onward.
0
0
0
0
P23
Maximum DHW setpoint (°C) (55°C …60°C) (131°F - 140°F)
60
60
60
60
P24
DHW start delay (sec)
35
35
35
35
P25
Manufacturer information. Set to 0. Ignore other options.
0
0
0
0
P26
Manufacturer information. Set to 9. Ignore other options.
9
9
9
9
P27
Manufacturer information. Set to 26. Ignore other options.
26
26
26
26
P28
Manufacturer information. Set to 0. Ignore other options.
0
0
0
0
P29
Manufacturer information. Set to 7. Ignore other options.
7
7
7
7
P30
Manufacturer information. Set to 10. Ignore other options.
10
10
10
10
P31
Manufacturer information. Set to 20. Ignore other options.
20
20
20
20
C00
Fault History C00
C01
Fault History C1
C02
Fault History C2
C03
Fault History C3
C04
Fault History C4
C05
Fault History C5
C06
Fault History C6
C07
Fault History (lock-out) C07
C08
Fault History (lock-out) C08
C09
Fault History (lock-out) C09
P42
Manufacturer information. Set to 0. Ignore other options.
0
0
0
0
P43
Manufacturer information. Set to 1. Ignore other options.
1
1
1
1
P44
°C/°F selection (also changes pressure to bar/psig)
1
1
1
1
P45
Manufacturer information. Set to 1. Ignore other options.
1
1
1
1
P46
Manufacturer information. Set to 63. Ignore other options.
63
63
63
63
P47
Manufacturer information. Set to 0. Ignore other options.
0
0
0
0
P48
Manufacturer Information. Shall be set to 0. Ignore other options.
0
0
0
0
P49
Manufacturer information. Set to 0. Ignore other options.
0
0
0
0
P50
Manufacturer information. Set to 25. Ignore other options.
25
25
25
25
P51
Manufacturer information. Set to 25. Ignore other options.
25
25
25
25
Parameter
Parameter Description
GMHB
227
NG
GMHB
227
LPG
GMHB
380
NG
GMHB
380
LPG
10.3.6 Description of Parameters- Continued
Parameter
Parameter Description
GMHB
227
NG
GMHB
227
LPG
GMHB
380
NG
GMHB
380
LPG
P52
Manufacturer information. Set to 90. Ignore other options.
90
90
90
90
P53
Manufacturer information. Set to 0. Ignore other options.
0
0
0
0
P54
Manufacturer information. Set to 20. Ignore other options.
20
20
20
20
P55
Manufacturer information. Set to 0. Ignore other options.
0
0
0
0
P56
DHW Frost protection enable/disable
0
0
0
0
P57
Manufacturer information. Set to 0. Ignore other options.
0
0
0
0
P58
Manufacturer information. Set to 0. Ignore other options.
0
0
0
0
P59
Manufacturer information. Set to 3. Ignore other options.
3
3
3
3
P60
Manufacturer information. Set to 1. Ignore other options.
1
1
1
1
P61
Manufacturer information. Set to 36. Ignore other options.
36
36
36
36
P62
Manufacturer information. Set to 9. Ignore other options.
9
9
9
9
P63
Manufacturer information. Set to 8. Ignore other options.
8
8
8
8
P64
Manufacturer information. Set to 0. Ignore other options.
0
0
0
0
P65
Manufacturer information. Set to 0. Ignore other options.
0
0
0
0
P66
Manufacturer information. Set to 98. Ignore other options.
98
98
98
98
P67
Manufacturer information. Set to 0. Ignore other options.
0
0
0
0
P68
Manufacturer information. Set to 0. Ignore other options.
0
0
0
0
P69
Manufacturer information. Set to 0. Ignore other options.
0
0
0
0
P70
Ignition fan speed (Fan speed = F70*100rpm)
(Consult factory before adjusting)
33
33
40
40
P71
Maximum fan speed(Fan speed = 5000+F71*10 rpm)
90
90
125
174
P72
Minimum fan speed (Fan speed = 750+F71*10 rpm)
115
108
95
135
P73
Manufacturer Information. Shall be set to indicated value. Ignore
other options.
5
5
6
6
P74
Manufacturer information. Set to 0. Ignore other options.
0
0
0
0
P75
Not used
-
-
-
-
P76
Manufacturer information. Set to 0. Ignore other options.
0
0
0
0
P77
Manufacturer information. Set to 0. Ignore other options.
0
0
0
0
P78
Manufacturer information. Set to 0. Ignore other options.
0
0
0
0
P79
DWH switch off offset (0..15°C; 0: fixed Off value; 1..15 Off=DHW
sF79)
0
0
0
0
P80
Manufacturer information. Set to 0. Ignore other options.
0
0
0
0
P81
Manufacturer information. Set to 1. Ignore other options.
1
1
1
1
P82
Manufacturer information. Set to 4. Ignore other options.
4
4
4
4
P83
Manufacturer information. Set to 25. Ignore other options.
25
25
25
25
P84
Manufacturer information. Set to 0. Ignore other options.
0
0
0
0
P85
Manufacturer information. Set to 0. Ignore other options.
0
0
0
0
P86
Manufacturer information. Set to 1. Ignore other options.
1
1
1
1
PN 240012369, REV A [08/31/2018]