OPERATION
17
500ze YM180 (12
−
2011)
The vacuum fan speed control must be reset after
the audible alarm sounds. To reset the vacuum
fan speed control system, stop the machine, place
the Drive lever in neutral, turn off the machine,
turn on the machine, and set the vacuum speed to
below 2400 rpm.
To continue cleaning beyond the 5
−
minute interval
and avoid resetting the vacuum fan speed control
system, reduce the vacuum fan speed to less
than 2400 rpm, for at least 30 seconds, before the
countdown bar expires at the end of the 5
−
minute
interval. The vacuum fan speed can again be set
above 2400 rpm for up to an additional 5 minutes.
If this is not done before the end of 5 minutes, the
vacuum fan speed control system will
automatically reduce the fan speed and the
system will need to be reset.
MASTER LIGHT SWITCH
Use the 3
−
position Master light switch to control
the headlights, overhead work lights, and rear fog
lights. Push the switch to the second position to
operate only the running lights. Push the switch to
the third position to operate the headlights and
allow use of the overhead work lights and rear fog
light.
Push the switch back to the first position to turn
off all lights.
NOTE: The rear fog light and overhead work light
switches must be in the on position for the lights
to function.