p. 31/37
temperature of the
remote room
thermostat
set-point of the room
thermostat
High set-point
temperature of the
boiler’s operating
thermostat
It is necessary to decrease the
set-point of the boiler’s
operating thermostat (it is
recommended to keep it above
60
o
C)
2.
High temperatures
in the heat
supplied rooms
High set-point
temperature of the
remote room
thermostat
It is necessary to decrease the
set-point of the room
thermostat
3.
The boiler is
powered on, but no
active electric
heaters
start signal is not
present
It is necessary to check the
status of the operation signal
of the boiler -
check the room
thermostat, as well as boiler’s
operating thermostat.
4.
Boiler’s
emergency
overheating
Absence of heat
consumption or
incorrect adjustment of
the parameters of the
boiler or poor
operation of the
heating installation
It is necessary to check the
correct operation process of
the heating installation and
eventually appropriate
adjustment of the operating
parameters of the electric
boiler –
this should be
performed by authorized
technician
. After the boiler is
cooled down to ambient
temperature and the reason for
boiler overheating is serviced
out, the protective cap of the
emergency overheating
thermostat should be
unscrewed, its rod should be
pressed until the thermostat is
reset and it’s cap should be
screwed back. The main
“POWER” switch is turned
OFF and back ON afterwards
and the system is thus
restarted.