3
2.2 Function of the Buttons
Wired Remote Controller XE72-44/E
Table 2
No.
Name
Function
1
SWING/ENTER
Function selection and cancellation.
Setting of the up and down swing function.
3
▲
①
②
①
②
7
▼
6
FAN
Setting of the auto/low/medium low/medium/medium high/ high fan speed.
4
MODE
Setting of the Cooling/Heating/Fan/Dry/Auto mode of the indoor unit.
5
FUNCTION
2
8
TIMER
Timer setting.
3+4
ON/OFF
6+7
Running temperature setting of the indoor unit, range:61~86°F(16~30
℃
).
Timer setting, range:0.5-24 hr.
3+7
▲+MODE
FAN+▼
Switchover among the functions of Turbo
/
WiFi/E-heater/X-fan etc..
Turn on/off the indoor unit.
▲+▼
4+7
MODE+▼
2+5
2+5
5+6
①
sensor ( 01 displayed on the timer area).
②
displayed on the timer area).
③
Under OFF state, the Celsius and Fahrenheit scales can be switched by
Under OFF state, it is available to go to the commissioning status by
TI
FU FAN
MER+FUNCTION
Press them for 5s under off state of the unit to Enter/Cancel the Memory
function(If memory is set, indoor unit after power failure and then power
recovery will resume the original setting state. If not, the indoor unit is
defaulted to be off after power recovery. Memory off is default before
delivery.).
TIMER+FUNCTION
By pressing them at the same time under off state of the unit, will be
displayed on the wired remote controller for the cooling only unit, while
will be displayed on the wired remote controller for the cooling and heating
unit.
FUNCTION
TIMER
the temperature display area by pressing “MODE”, then adjust the options
which is shown on the timer area by pressing
“▲”
and
“▼”.
There are totally
four options, as follows:
The return air temperature sensor is selected under the cooling, dry, or
dry, or fan mode; while the return air temperature sensor is selected under
the heating mode. (04 is displayed on the timer display area).
Indoor ambient temperature is sensed by the return air temperature
MODE
Reset the WiFi function: Under off status, press “FUNCTION” + “FAN”
combination buttons on its wired controller for 5s. Once “oC” is displayed,
this indicates that reset was successful.
Indoor ambient temperature is sensed by the wired controller (02
④
fan mode; while the wired controller temperature sensor is selected under
the heating or auto mode. (03 is displayed on the timer area).
The wired controller temperature sensor is selected under the cooling,
Upon startup of the unit without malfunction or under off state of the
unit,press them at the same time for 5s to enter the lock state, in which
case, any other buttons won’t respond the press. Repress them for 5s to
quit this state.
Under OFF state, it is available to go to the commissioning status by
pressing “
FUNCTION
” and “
TIMER
” for five seconds. Press “
MODE
” button to
until “01” icon is shown at the temperature display area. The setting status
will be shown at timer area. Press “
▲
” and “
▼
” button to adjust and two
options are available:
①
Three low levels (01) ;
②
Three high levels (02).
5s.