background image

I FEEL


NOTE

CLOCK

SLEEP

Press this button, can select Sleep 1 (     1),

Sleep 2 (      2), Sleep 3 (      3) and cancel the

Sleep, circulate between these, after electrified, 

Sleep Cancel is defaulted.

Sleep 1 is Sleep mode 1, in Cool modes; sleep

 

Clock time adopts 24-hour mode.

 

The interval between two operations can

'

t exceed 5s. 

Otherwise, remote controller will quit setting status. 
Operation for TIMER ON/TIMER OFF is the same.

9

status after run for one hour, the main unit setting 

temperature will increase 1 , two hours, setting 

temperature increased 2

, then the unit will run at

this setting temperature; In Heat mode: sleep 

Press this button to set clock time. "      " icon on 

remote  controller  will  blink.  Press  " "  or  " " 

button within 5s to set clock time. Each pressing of 

" "  or  " "  button,  clock  time  will  increas  e  or 

decrease  1  min.  If  hold  " "  or  " "  button  ,  2s 

later,  time  will  change  quickly.  Release  this  button 

when  reaching  your  required  time.  Press  "CLOCK" 

button to confirm the time. "     " icon stops blink-

ing.

status after run for one hour, the setting tempera- 

ture will decrease 1 , two hours, setting tempera-

ture will decrease 2 , then the unit will run at this 

setting temperature.

Sleep 2 is sleep mode 2, that is air conditioner

will run according to the presetting a group of

sleep temperature curve.

Sleep 3-the sleep curve setting under Sleep

mode by DIY;

(1)Under Sleep 3 mode, press “TURBO” button for a

long time, remote controller enters into user indi-

viduation sleep setting status, at this time, the time

of remote controller will display “1hour”, the setting

temperature “88” will display the corresponding

temperature of last setting sleep curve and blink

(The first entering will display according to the

NOTE

Under on and off status, you can set T-OFF or T-ON 

 

simultaneously. 

Before setting T-ON or T-OFF, please adjust the 

clock time.

After starting up T-ON or T-OFF,set the constant 

circulating valid.

After that, air conditioner will be turned on or turned 

off according to setting time. ON/OFF button has no 

effect on setting. If you don’ t need this function, 

please use remote controller to cancel it.

initial curve setting value of original factory);

(2)Adjust “

” and “

” button, could change the

corresponding setting temperature, after adjusted,

press “TURBO” button for confirmation;

(3) At this time, 1hour will be automatically

increased at the timer position on the remote con-

trol, (that are "2hours" or "3hours" or "8hours"), the

place of setting temperature "88" will display the

corresponding temperature of last setting sleep

curve and blink;

(4) Repeat the above step (2)~(3) operation, until

8 hours temperature setting finished, sleep,curve

setting finished, at this time, the remote controller

will resume the original timer display; temperature

display will resume to original setting temperature.

Sleep3- the sleep curve setting under Sleep

mode by DIY could be inquired:

The user could accord to sleep curve setting

method to inquire the presetting sleep curve, enter

into user individuation sleep setting status, but do

not change the temperature, press "TURBO" button

directly for confirmation. Note: In the above preset-

ting or enquiry procedure, if continuously within

10s, there is no button pressed, the sleep curve

setting within 10s, there is no button pressed, the

sleep curve setting status will be automatically quit

and resume to display the original displaying. In

the presetting or enquiry procedure, press

"ON/OFF" button, "MODE" button, "SLEEP" button,

the sleep curve setting or enquiry status will quit

similarly.

Press this button to start I FEEL function and "      " 

will be displayed on the remote controller. After this

function is set, the remote controller will send the 

detected ambient temperature to the controller 

and the unit will automatically adjust the indoor te-

mperature according to the detected temperatu

 

re. 

Press this button again to cancel I FEEL function 

and "      " will disappear. 

Please put the remote controller near user when

 

 this

function is set. Do not put the remote contro

 

ller 

near the object of high temperature or low temper-

ature in order to avoid detecting inaccurate am

 

bie-

nt temperature.When I FEEL function is turned on, 

the remote controller should be put within the a

 

rea 

where indoor unit can receive the signal sent by

 

 

 the 

remote controller. 

Summary of Contents for Vireo Gen 3 3VIR09HP115V1AH

Page 1: ...ers printer qxp_Layout 1 2 21 17 2 10 PM Page 1 Models 3VIR09HP115V1AH 3VIR12HP115V1AH 3VIR09HP230V1AH 3VIR12HP230V1AH 3VIR18HP230V1AH 3VIR24HP230V1AH HIGH WALL DUCTLESS AIR CONDITIONING HEATING SYSTE...

Page 2: ...ration and introduction of remote controller Clean and maintenance Checked items before maintenance Installation notice Installation of indoor unit Test and operation Configuration of connection pipe...

Page 3: ...responsibilities when personal injury or property loss is caused by the following reasons This symbol indicates the possibility of death or serious injury This symbol indicates the possibility of inj...

Page 4: ...rference to radio communications 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Howe...

Page 5: ...0cm separation distance will be maintained between the device excluding its handset and users Cet appareil est conforme aux limites d exposition au rayonnement RF stipul es par la FCC et l IC pour une...

Page 6: ...r conditioner s specification and local codes Unstable power supply or incorrect wiring may result in electrical shock fire hazard or unit malfunction Grounding of units must comply with the National...

Page 7: ...an outside wall Wire to code see submittals Power and control wiring from the outdoor unit to the indoor unit must be continuous A circuit breaker must be installed in the line The yellow green wire...

Page 8: ...If the supply wiring is damaged it must be replaced by a licensed HVAC technician or other licensed electrical professional Connect air conditioner to a dedicated circuit breaker Disconnect power supp...

Page 9: ...o malfunction Do not step on or put heavy objects on top panel of outdoor unit It may damage the unit or cause personal injury If any of the following occur turn off the air conditioner and disconnect...

Page 10: ...turn off the air conditioner When the air conditioner is turned on it will operate under auto mode Display Temp indicator Power indicator This is the general introduction and the color of indicator i...

Page 11: ...t Clock Operation mode Set time TIMER ON TIMER OFF Turbo mode Send signal Auto mode Cool mode Left right swing Up down swing Child lock Dry mode Fan mode Heat mode Temp I feel Set fan speed display ty...

Page 12: ...multifunction For the functions which the model doesn t have if press the corresponding button on the remote controller the unit will keep the original running status After putting through the power...

Page 13: ...angle When selecting air condition er is blowing fan at xed position Horizontal louver will stop at the xed position Press or button once increase or decr ease set temperature 1 F Holding or button 2s...

Page 14: ...function please use remote controller to cancel it initial curve setting value of original factory 2 Adjust and button could change the corresponding setting temperature after adjusted press TURBO bu...

Page 15: ...usted Under 8 heating function set temperature can t be adjusted Press TURBO button and the remote controller won t send signal Sleep function and 8 heating function can t operate at the same time If...

Page 16: ...f the auto clean function When the auto clean func tion is turned on indoor unit displays CL During the auto clean process of evaporator the unit will perform fast cooling or fast heating There may be...

Page 17: ...on 1 2 3 Clean and maintenance 2 WARNING WARNING Please contact qualified professionals for service Error Code Error code F2 E8 Troubleshooting C5 F0 F1 U8 H6 H3 E1 E5 E6 Notice for recovery 1 Clean s...

Page 18: ...les Check the batteries If the power of batter s e i o l is too w please rep lace them Under heating mode indoor temperature is reached to set temp erature Power failure Is plug loose In order to prev...

Page 19: ...system pre ssure rise or compressor rupture resulting in injury Measuring tape spanner Inner hexagon When installing or moving this unit do not charge the refrigerant which is not comply with that on...

Page 20: ...ith the requirement of air conditioner Unstable power supply or incorrect wiring or malfunction Pl ease install proper power supply cables before using the air conditioner grounding wire of power sock...

Page 21: ...hole bellmouth Pretighten the union nut with hand Please refer to the actual circumstances for the number of screws and the position of screws rear right 1 16 The pipe can be led out in the direction...

Page 22: ...ross hole at the back of indoor unit and then pull it out from the front side panel screw wiring cover outlet pipe drain hose All wires of indoor unit and outdoor unit should be If the length of power...

Page 23: ...r cord for installation when binding th em When binding to a certain degree sep arate the indoor power and then separate the drain hose Do not bend the drain hose too excessively in order to prevent b...

Page 24: ...tion or damage the parts Is there any obstruction in the air inlet and outlet Is heat insulation of pipe line sufficient It may cause malfunction or damage the parts The gas valve and liquid valve of...

Page 25: ...f additional refrigerant charging amount on the basis of liquid pipe Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging amount per meter Basing on t...

Page 26: ...tdoor side NOTICE Maximum heating NOTE 30 18 86 65 Outer diameter mm The operating temperature range outdoor temper ature for cooling is 29 C 20 F 50 C 122 F for heating is 30 C 22 F 30 C 86 F ature f...

Page 27: ...ervice the unit Some basic maintenance might be all you need The outdoor unit will greatly benefit from a good hosing off especially in treed areas where seeds and other debris can stick to coil fins...

Page 28: ...R CHANGED BY ANY DISTRIBUTOR DEALER OR OTHER PERSON WHATSOEVER THIS WARRANTY DOES NOT COVER 1 Labor or other costs incurred for diagnosing repairing removing installing shipping servicing or handling...