background image

NOTE

Introduction for buttons on 

remote controller 

Press this button to turn on the unit. Press this 

button  again to turn off the unit.

Press this button to select your required operat-

ion mode.

MODE

AUTO COOL DRY

FAN

HEAT

TURBO

adjust fan blowing angle.

Under COOL or HEAT mode, press this button to

When selecting heating mode, the air condition-

er operates under heat mode. Press " " or "    " 

button to adjust set temperature. Press "FAN" 

button to adjust fan speed. Press "     " / "    " 

button to adjust fan blowing angle. (Cooling 

only unit won't receive heating mode signal. If 

setting heat mode with remote controller, press 

ON/OFF button can’t start up the unit).  

NOTE

When selecting auto mode, air conditioner will 

operate automatically according to ex-factory 

setting. Press "FAN" button can adjust fan 

speed. Press "     " / "    " button can adjust fan 

blowing angle.

After selecting cool mode, air conditioner will 

operate under cool mode. Press " " or "    " 

button to adjust set temperature. Press "FAN" 

button to adjust fan speed. Press "    " / "    " 

button to adjust fan blowing angle.

When selecting dry mode, the air conditioner 

operates at low speed under dry mode.  Under 

dry mode, fan speed can’ t be adjusted. Press  

"     " / "     " button to adjust fan blowing angle.

When selecting fan mode, the air conditioner 

will only blow fan, no cooling and no heating. All 

indicators are OFF. Press "FAN" button to 

adjust fan speed. Press "     " / "    " button to

 

For preventing cold air, after starting up heating mode, 
indoor unit will delay 1~5 minutes to blow air (actual 
delay time is depend on indoor ambient temperature).
Set temperature range from remote controller: 
16~30

 (61-86°F);

 

Under auto mode, temperature can be displayed; 

 

Under auto mode, set temperature can be adjusted.
This mode indicator is not available for some models.

FAN

,

, to

, then back to Auto.

NOTE

This button is used for setting Fan Speed in the 

sequence that goes from AUTO,

,     ,

,

This is a general use remote controller. It could be 

used for the air conditioner with multifunction. For the 

functions which the model doesn't have, if press the 

corresponding button on the remote controller, the unit 

will keep the original running status.

 

After putting through the power, the air conditioner will 

give out a sound. Power indicator "     " is ON. After 

that, you can operate the air conditioner by using 

remote controller.

 

Under on status, pressing the button on the remote 

controller, the signal icon "       " on the display of 

remote controller will blink once and the air conditioner 

will give out a " di " sound, which means the signa has 

been sent to the air conditioner.

 

As for the models with functions of WiFi or wired 

controller, the indoor unit must has been controlled by 

standard remote controller under auto mode first, and 

then the function of adjustable temperature under auto 

mode can be realized by APP or the wired controller.

 

This remote controller can adjust the temperature 

under auto mode. When matching with the unit which 

is without the function of adjustable temperature under 

auto mode, the set temperature under auto mode may 

be invalid, or the displayed set temperature on the unit 

is not same as that on the remote controller under 

auto mode.

7

Under AUTO speed, air conditioner will select proper 
fan speed automatically according to factory default
setting.
It

'

s low fan speed under dry mode.

X-FAN function: Holding fan speed button for 2s in
cool or dry mode, the icon 

"

      

"

 is displayed and the

indoor fan will continue operation for a few minutes in 
order to dry the indoor unit even though you have
turned off the unit. After energization, X-FAN OFF is
defaulted. X-FAN is not available in auto, fan or heat
mode.
This function indicates that moisture on evaporator of
indoor unit will be blowed after the unit is stopped to
avoid mould.

 

Having set X-FAN function on: After turning off the
unit by pressing ON/OFF button, indoor fan will
continue running for a few minutes at low speed. In
this period, hold fan speed button for 2s to stop
indoor fan directly.
Having set X-FAN function off: After turning off the
unit by pressing ON/OFF button, the complete unit
will be off directly.

ON/OFF

Summary of Contents for Vireo Gen 3 3VIR09HP115V1AH

Page 1: ...ers printer qxp_Layout 1 2 21 17 2 10 PM Page 1 Models 3VIR09HP115V1AH 3VIR12HP115V1AH 3VIR09HP230V1AH 3VIR12HP230V1AH 3VIR18HP230V1AH 3VIR24HP230V1AH HIGH WALL DUCTLESS AIR CONDITIONING HEATING SYSTE...

Page 2: ...ration and introduction of remote controller Clean and maintenance Checked items before maintenance Installation notice Installation of indoor unit Test and operation Configuration of connection pipe...

Page 3: ...responsibilities when personal injury or property loss is caused by the following reasons This symbol indicates the possibility of death or serious injury This symbol indicates the possibility of inj...

Page 4: ...rference to radio communications 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Howe...

Page 5: ...0cm separation distance will be maintained between the device excluding its handset and users Cet appareil est conforme aux limites d exposition au rayonnement RF stipul es par la FCC et l IC pour une...

Page 6: ...r conditioner s specification and local codes Unstable power supply or incorrect wiring may result in electrical shock fire hazard or unit malfunction Grounding of units must comply with the National...

Page 7: ...an outside wall Wire to code see submittals Power and control wiring from the outdoor unit to the indoor unit must be continuous A circuit breaker must be installed in the line The yellow green wire...

Page 8: ...If the supply wiring is damaged it must be replaced by a licensed HVAC technician or other licensed electrical professional Connect air conditioner to a dedicated circuit breaker Disconnect power supp...

Page 9: ...o malfunction Do not step on or put heavy objects on top panel of outdoor unit It may damage the unit or cause personal injury If any of the following occur turn off the air conditioner and disconnect...

Page 10: ...turn off the air conditioner When the air conditioner is turned on it will operate under auto mode Display Temp indicator Power indicator This is the general introduction and the color of indicator i...

Page 11: ...t Clock Operation mode Set time TIMER ON TIMER OFF Turbo mode Send signal Auto mode Cool mode Left right swing Up down swing Child lock Dry mode Fan mode Heat mode Temp I feel Set fan speed display ty...

Page 12: ...multifunction For the functions which the model doesn t have if press the corresponding button on the remote controller the unit will keep the original running status After putting through the power...

Page 13: ...angle When selecting air condition er is blowing fan at xed position Horizontal louver will stop at the xed position Press or button once increase or decr ease set temperature 1 F Holding or button 2s...

Page 14: ...function please use remote controller to cancel it initial curve setting value of original factory 2 Adjust and button could change the corresponding setting temperature after adjusted press TURBO bu...

Page 15: ...usted Under 8 heating function set temperature can t be adjusted Press TURBO button and the remote controller won t send signal Sleep function and 8 heating function can t operate at the same time If...

Page 16: ...f the auto clean function When the auto clean func tion is turned on indoor unit displays CL During the auto clean process of evaporator the unit will perform fast cooling or fast heating There may be...

Page 17: ...on 1 2 3 Clean and maintenance 2 WARNING WARNING Please contact qualified professionals for service Error Code Error code F2 E8 Troubleshooting C5 F0 F1 U8 H6 H3 E1 E5 E6 Notice for recovery 1 Clean s...

Page 18: ...les Check the batteries If the power of batter s e i o l is too w please rep lace them Under heating mode indoor temperature is reached to set temp erature Power failure Is plug loose In order to prev...

Page 19: ...system pre ssure rise or compressor rupture resulting in injury Measuring tape spanner Inner hexagon When installing or moving this unit do not charge the refrigerant which is not comply with that on...

Page 20: ...ith the requirement of air conditioner Unstable power supply or incorrect wiring or malfunction Pl ease install proper power supply cables before using the air conditioner grounding wire of power sock...

Page 21: ...hole bellmouth Pretighten the union nut with hand Please refer to the actual circumstances for the number of screws and the position of screws rear right 1 16 The pipe can be led out in the direction...

Page 22: ...ross hole at the back of indoor unit and then pull it out from the front side panel screw wiring cover outlet pipe drain hose All wires of indoor unit and outdoor unit should be If the length of power...

Page 23: ...r cord for installation when binding th em When binding to a certain degree sep arate the indoor power and then separate the drain hose Do not bend the drain hose too excessively in order to prevent b...

Page 24: ...tion or damage the parts Is there any obstruction in the air inlet and outlet Is heat insulation of pipe line sufficient It may cause malfunction or damage the parts The gas valve and liquid valve of...

Page 25: ...f additional refrigerant charging amount on the basis of liquid pipe Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging amount per meter Basing on t...

Page 26: ...tdoor side NOTICE Maximum heating NOTE 30 18 86 65 Outer diameter mm The operating temperature range outdoor temper ature for cooling is 29 C 20 F 50 C 122 F for heating is 30 C 22 F 30 C 86 F ature f...

Page 27: ...ervice the unit Some basic maintenance might be all you need The outdoor unit will greatly benefit from a good hosing off especially in treed areas where seeds and other debris can stick to coil fins...

Page 28: ...R CHANGED BY ANY DISTRIBUTOR DEALER OR OTHER PERSON WHATSOEVER THIS WARRANTY DOES NOT COVER 1 Labor or other costs incurred for diagnosing repairing removing installing shipping servicing or handling...

Reviews: