OUTDOOR UNIT INSTALLATION
Drain Joint
Chassis
Bottom
Drain pipe mounting hole
The unit should be located with the unit support feet firmly on the equipment pad.
If the outdoor unit is exposed to wind, it must be properly secured.
WARNING
Model
A
B
C
D
E
UMAT18HP230V1AO
37-5/8
15-5/8
27-1/2
22
14-1/8
(955)
(396)
(700)
(560)
(360)
UMAT24HP230V1AO
38-5/8
16-3/4
31-1/8
24
15-1/2
UMAT30HP230V1AO
(980)
(427)
(790)
(610)
(395)
UMAT36HP230V1AO
43-5/8
17-3/8
43-1/4
24-7/8
15-3/4
UMAT42HP230V1AO
(1107)
(440)
(1100)
(631)
(400)
UMAT48HP230V1AO
37-3/4
16-1/4
53-1/8
22-1/2
14-3/4
(958)
(412)
(1349)
(572)
(376)
OUTDOOR UNIT DIMENSIONS
in (mm)
Condensate Drainage of the Outdoor Unit
The outdoor unit should be installed with a drain pipe to
drain condensate water during the heating mode.
1. Insert the drain joint (included) into the selected
hole located on the bottom of the base pan and
then connect the drain hose (field supplied) to
the drain joint.
2. All other holes must be sealed with plugs (included)
to avoid water leaks, except for the drain pipe
mounting hole.
3. Route drain hose to safe location for disposing of
condensate water.
13