Step
Remove the screws fixing motor clamp
and then remove the motor clamp.
Remove the screws at the connection
place of cross flow blade and motor; lift
the motor and cross flow blade upwards
to remove them.
Remove the bearing holder sub-assy.
Remove the screw fixing step motor and
then remove the step motor.
Screws
Screw
Motor clamp
9. Remove motor and cross flow blade
Motor
C
ross flow
Holder
sub-assy
Step motor
Screws
a
b