background image

IC STATEMENT

This equipment complies with FCC’s and IC’s RF radiation exposure limits set forth 
for an uncontrolled environment. The antenna(s) used for this transmitter must be 
installed and operated to provide a separation distance of at least 20 cm from all 
persons and must not be collocated or operating in conjunction with any 

other 

antenna or transmitter. Installers must ensure that 20cm separation distance will 
be maintained between the device (excluding its handset) and users. 

   

Cet appareil est conforme aux limites d’exposition au rayonnement RF stipulées 
par la FCC et l’IC pour une utilisation dans un environnement non contrôlé. Les   

antennes utilisées pour cet émetteur doivent être installées et doivent fonctionner 
à au moins 20 cm de distance des utilisateurs et ne doivent pas être placées près  
d’autres antennes ou émetteurs ou fonctionner 

avec ceux-ci. Les installateurs 

doivent s’assurer qu’une distance de 20 cm sépare l’appareil (à l’exception du   
combiné) des utilisateurs.

Summary of Contents for Livo Gen 3

Page 1: ...HIGH WALL DUCTLESS AIR CONDITIONING HEATING SYSTEM OWNER S MANUAL TWD 1594 Livo owners printer qxp_Layout 1 2 21 17 2 10 PM Page 1...

Page 2: ......

Page 3: ...LIVV09HP115V1AH LIVV12HP115V1AH...

Page 4: ...01 06 14 15 16 18 Parts name 21 22 OPERATION OF WIRELESS REMOTE CONTROLLER Clean and maintenance Checked items before maintenance Installation notice Installation of indoor unit Test and operation Co...

Page 5: ...ymbol indicates the possibility of death or serious injury This symbol indicates the possibility of injury or damage to property Indicates important but not hazard related information used to indicate...

Page 6: ...allation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications H...

Page 7: ...20cm separation distance will be maintained between the device excluding its handset and users Cet appareil est conforme aux limites d exposition au rayonnement RF stipul es par la FCC et l IC pour un...

Page 8: ...ir conditioner Unstable power supply or incorrect wiring may result in electric shock fire haza rd or malfunction Please install proper power supply cables before using the air conditioner The groundi...

Page 9: ...must be po sitioned so that the plug is accessible For the air conditioner with plug the plug should be re achable after finishing in stallation For the air conditioner with out plug a circuit breaker...

Page 10: ...by the manufacturer its ser vice agent or similarly qua lified persons in order to avoid a hazard Do not connect air condi tioner to multi purpose soc ket Otherwise it may cau se fire hazard Do discon...

Page 11: ...It may cause mal function Do not step on top panel of outdoor unit or put heavy objects It may cause dam age or personal injury When below phenomenon occurs please turn off air conditioner and discon...

Page 12: ...controller is lost or damaged please use aux button to turn on or turn off the air conditioner The operation in details is as below As shown in the figure open panel and press aux button to turn off...

Page 13: ...ng in cooling mode with low fan speed 2 If the RoomTemperature is between 4 F higher than and 4 F less than the set temperature the system will cycle 6 minutes ON and 4 minutes OFF in cooling mode The...

Page 14: ...ignal has been sent to the air conditioner Under off status set temperature and clock icon will be displayed on the display of remote controller If timer on timer off and light functions are set the c...

Page 15: ...indicates that moisture on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould Having set X FAN function on After turning off the unit by pressing ON OFF button indoor fa...

Page 16: ...again to exit turbo function and icon will disappear button 6 Press or button once increase or decrease set temperature 1 1 F Holding or button 2s later set temperature on remote controller will chang...

Page 17: ...r time will change quickly Release this button when reaching your required time Note Clock time adopts 24 hour mode The interval between two operations can t exceeds 5s Otherwise remote contro ller wi...

Page 18: ...it Function introduction for combination buttons Energy saving function Under cooling mode press TEMP and CLOCK buttons simultaneously to start up or turn off energy saving function When energy saving...

Page 19: ...nction will cancel sleep function Temperature display switchover function I FEEL Function Under OFF status press and MODE buttons simultaneously to switch temp erature display between and Press and MO...

Page 20: ...r will automatically adjust the indoor temperature according to the detected tempera OPERATION OF WIRELESS REMOTE CONTROLLER CHANGING BATTERIES AND ADDITIONAL NOTES To change batteries slide cover off...

Page 21: ...s o p s i d e s a e l P s l a i r recycling unit e s a e l p r e n o i t i d n o c r i a e h t e s o p s i d o t t n a w u o y f I for the correct disposal method Turn off the air conditioner and disc...

Page 22: ...tion of panel or other parts due to the change of temp erature In order to prevent blowing out cold air indoor unit will be started after delaying for several minutes which is a normal phenomenon Chec...

Page 23: ...accident 1 minute sure that the unit is running in cooling mode Then fully close the valve at high pressure side liquid valve About 30 40 seconds later fully close the valve at low pressure side gas v...

Page 24: ...the requirement of air conditioner Unstable power supply or incorrect wiring or malfunction Pl ease install proper power supply cables before using the air conditioner grounding wire of power socket 5...

Page 25: ...es when opening the hole bellmouth Pretighten the union nut with hand Please refer to the actual circumstances for the number of screws and the position of screws rear right 1 18 The pipe can be led o...

Page 26: ...reachable after finishing installation For the air conditioner without plug an air switch must be installed in the line The air switch should be all pole parting and the contact parting distance shoul...

Page 27: ...e gap between pipes and wall hole with sealing gum Fix the wall pipe Check if the indoor unit is installed firmly and closed to the wall Bind up the connection pipe power cord and Remove the wire clip...

Page 28: ...let and outlet It may cause insufficient cooling heating capacity It may cause malfunction or damage the parts The gas valve and liquid valve of connection pipe are open completely The dust and sundri...

Page 29: ...ethod of additional refrigerant charging amount on the basis of liquid pipe Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging amount per meter Basi...

Page 30: ...unit is 18 0 F 46 1 115 F for heat pump unit is 20 4 F 46 1 115 F For some models Outdoor side DB WB F hard mold Maximum cooling 26 7 19 4 80 67 46 1 23 9 115 75 Maximum heating NOTE 26 7 80 23 9 18...

Page 31: ......

Page 32: ...COVER 1 Labor or other costs incurred for diagnosing repairing removing installing shipping servicing or handling of either defective parts or replacement parts or new units 2 Product cleaning requir...