U-Match Series DC Inverter Service Manual
86
①
. The power source capacity must be the sum of the air conditioner current and the current of other electrical
appliances. When the current contracted capacity is insufficient, change the contracted capacity.
②
. When the voltage is low and the air conditioner is difficult to start, contact the power company to raise the voltage.
4.2 Electrical Wiring
(1) For solid core wiring (Figure 3-4-1)
1) Cut the wire end with a wire cutter or wire-cutting pliers, then strip the insulation about 25mm (1
inch).
2) Using a screwdriver, remove the terminal screw(s) on the terminal board.
3) Using pliers, bend the solid wire to form a loop suitable for the terminal screw.
4) Shape the loop wire properly, place it on the terminal board and tighten securely with the
terminal screw using a screwdriver.
(2) For strand wiring (Figure 3-4-1).
1) Cut the wire end with a wire cutter or wire-cutting pliers, then strip the insulation about 10mm
(3/8inch).
2) Using a screwdriver, remove the terminal screw (s) on the terminal board.
3) Using a round terminal fastener or pliers, securely clamp a round terminal to each stripped wire
end.
4) Position the round terminal wire, and replace and tighten the terminal screw with a screwdriver
(Figure 3-4-2).
10
mm
(3
/8i
nc
h)
A Solid wire
B Strand wire
Solderless
terminal
Insulation layer
25
mm
(1
in
ch
)
Figure 3-4-1
Screw with
special washer
Round
terminal
Terminal
board
Screw with
special washer
Round
terminal
Wire
Wire
Insulation tube
Insulation tube
Cord clamp
Figure 3-4-2 Figure 3-4-3
(3) How to fix connection cord and power cord by cord clamp
After passing the connection cord and power cord through the insulation tube, fasten it with the cord
Summary of Contents for GKH18D3FI
Page 1: ...U MATCH SERIES DC INVERTER AIR CONDITIONERS SERVICE MANUAL T1 R410A 60Hz GC201410...
Page 4: ...U Match Series DC Inverter Service Manual 1 PRODUCT...
Page 16: ...U Match Series DC Inverter Service Manual 13 CONTROL...
Page 55: ...U Match Series DC Inverter Service Manual 52 INSTALLATION...
Page 96: ...U Match Series DC Inverter Service Manual 93 MAINTENANCE...
Page 112: ...U Match Series DC Inverter Service Manual 109 H6 DC fan error...
Page 121: ...U Match Series DC Inverter Service Manual 118 Model GUHD24ND3FO Model GUHD30ND3FO...
Page 122: ...U Match Series DC Inverter Service Manual 119 Model GUHD36ND3FO Model GUHD42ND3FO...
Page 126: ...U Match Series DC Inverter Service Manual 123 Model GKH48D3FI...
Page 191: ...U Match Series DC Inverter Service Manual 188 JF00302305...