U-Match Series DC Inverter Service Manual
128
3. Remove gas liquid
separator.
1. Discharge the refrigerant inside the pipeline and
recycle the refrigerant during discharging;
2. Unsolder the 4-way valve assy from gas liquid
separator;
3. Remove the gas liquid separator.
4. Remove compressor
1. Discharge the refrigerant inside the pipeline and
recycle the refrigerant during discharging;
2. Unsolder the 4-way valve assy from
compressor;
3. Remove the nut fixing compressor;
4. Take away the compressor from chassis.
5. Assemble unit
Assemble the unit in the reverse procedures of
disassembly.
4.2 Indoor Unit
4.2.1 Duct type
Removal and Assembly of Fan Motor
Remarks: Before removing the fan, make sure to cut off the power firstly.
Step
Illustration
Handling Instruction
1. Unplug the motor
cables
Cut off the power supply of indoor unit. Use
screwdriver to remove the electric box cover
and unplug the motor cables in electric box.
2. Remove the filter
sub-assembly and air inlet
cover board
Remove the filter sub-assembly from the air
inlet frame and use screwdriver to remove
the air inlet cover board.
Summary of Contents for GKH18D3FI
Page 1: ...U MATCH SERIES DC INVERTER AIR CONDITIONERS SERVICE MANUAL T1 R410A 60Hz GC201410...
Page 4: ...U Match Series DC Inverter Service Manual 1 PRODUCT...
Page 16: ...U Match Series DC Inverter Service Manual 13 CONTROL...
Page 55: ...U Match Series DC Inverter Service Manual 52 INSTALLATION...
Page 96: ...U Match Series DC Inverter Service Manual 93 MAINTENANCE...
Page 112: ...U Match Series DC Inverter Service Manual 109 H6 DC fan error...
Page 121: ...U Match Series DC Inverter Service Manual 118 Model GUHD24ND3FO Model GUHD30ND3FO...
Page 122: ...U Match Series DC Inverter Service Manual 119 Model GUHD36ND3FO Model GUHD42ND3FO...
Page 126: ...U Match Series DC Inverter Service Manual 123 Model GKH48D3FI...
Page 191: ...U Match Series DC Inverter Service Manual 188 JF00302305...