SPLIT TYPE
3. Nomenclature
G
RS
-
C
Q
16
Pd
/
Na
E
-
M
(O)
1
2
3
4
5
6
7
8
9
10
NO.
Description
Options
1
GREE
G-GREE Air to water heat pump
2
Heat Pump Water Heater
RS
3
Heating Mode
S= Static; C=Circulating
4
Function
Q=Multi-function; Omit=Single-function
5
Nominal Heating Capacity
6.0=6.0kW; 8.0=8.0kW;10=10kW; 12=12kW; 14=14kW; 16=16kW
6
Compressor Style
Pd=DC Inverter; Omit=On/Off
7
Refrigerant
Na=R410A
8
Design Serial Number
B,C,D,E......
9
Power Supply
K=220-240V,~,50Hz;M=380-415V,3N~,50Hz;H=380V,3N~,60Hz
10
Indoor and Outdoor Unit Code
I=Indoor unit; O=Outdoor unit
Model Line-Up
Model Name
Capacity
Power supply
Heating
1
,kW
Cooling
2
,kW
GRS-CQ8.0Pd/NaE-K
8
7.8
220-240VAC 50Hz
GRS-CQ10Pd/NaE-K
10
8.2
GRS-CQ12Pd/NaE-K
12
12.5
GRS-CQ14Pd/NaE-K
14
13.5
GRS-CQ16Pd/NaE-K
15.5
14.5
GRS-CQ12Pd/NaE-M
12
13.5
380-415VAC 3Ph 50Hz
GRS-CQ14Pd/NaE-M
14
14.5
GRS-CQ16Pd/NaE-M
15.5
15
Notes
(a)
1
Capacities and power inputs are based on the following conditions:
Indoor Water Temperature 30°C/35°C, Outdoor Air Temperature 7°C DB/6°C WB;
(b)
2
Capacities and power inputs are based on the following conditions:
Indoor Water Temperature 23°C/18°C, Outdoor Air Temperature 35°C DB/24°C WB.
Operation Range
Mode
Heat Source Side Temperature (°C)
User Side Temperature (°C)
Heating
-20~35
25~55
Cooling
10~48
7~25
Water Heating
-20~45
40~80