Air-to-water Heat Pump Split Versati
43
SPLIT TYPE
T-SEN12
CN13
Gas Temperature Sensor of the PHE
Leaving Water Temperature of the Electric Heate
T-SEN13
CN14
Remote room temp sensor2(Reserved)
T-SEN11
CN15
Remote room temp sensor1
T-SEN4
CN20
Reserved
T-SEN2
CN21
Reserved
T-SEN3
CN22
Reserved
T-SEN10
CN24
Solar water-in temp sensor
T-SEN7
CN29
Solar water-out temp sensor
T-SEN9
CN30
Solar board temp sensor
T-SEN8
CN32
Reserved
SW_SO
CN16
Solar waterflow switch
SW_PO/OV_PUMP
CN17
Reserved
SW_IN
CN25
Indoor units waterflow switch
OVC-HEAT1
CN26
E-heater of indoor unit1 adhesion-proof protection detector
OVC-HEAT2
CN27
E-heater of indoor unit2 adhesion-proof protection detector
OVC-WT_HEAT
CN28
E-heater of water tank adhesion-proof protection detector
DOOR_IN
CN23
Door detection input
CN18
CN18
Power supply interface of the thermostat (220~240V)
HEAT_M2
CN31
Power supply interface and control signal of the thermostat (24V)
COOL_M2
24VAC
OFF2
OFF1
CN33
Control signal of the thermostat
HEAT_M1
COOL_M1
COM_OUT
CN5
Connect to AP2
COM_MANUAL
CN6
Connect the wired controller
COM_BMS
CN19
Reserved
OTHER_HEAT_DCOUT
X1
The dc output of assistant heat
OTHER_HEAT_DCIN
X2
The dc input of assistant heat
RUN
X15
Running indicator
ERR
X19
Error indicator
WT _HEAT
X16
E-heater of water tank
HEAT1
X17
E-heater 1
HEAT2
X18
E-heater 2
BAN_HEAT
X3
Reserved
PUMP1
X5
Reserved
OTHER_HEAT
X6
Assistant heat by 220VAC
PUMP2
X9
Reserved
X10
X10
Reserved