Great Plains
| 401-647M | 2019-06-11
Table of Contents
Index
180
3PYPA
Table of Contents
Index
Appendix R - Row-Pro™
Row-Pro™ Adjustments
Refer to Figure 189
Load Cell Reading
These readings are displayed and adjusted from the
IntelliAg
®
seed monitor console.
Control Mode:
Auto
is the normal running mode.
Manual
is used to control the valves only when the
operator touches the increase or decrease icon on the
work screen.
Monitor Only
:
This screen disables control, but still
reports sensor feedback. From there, press the
Down
Pressure Diagnostic
key and then press the
Float
Mode ON
button to release all of the air from the system.
Next, press the
Float Mode OFF
button. Stay on the
Diagnostic
screen and make a planting pass. Note the
pressure displayed on the
Diagnostic
screen and then
evaluate the seed trench. If the seed trench results are
acceptable, use the displayed pressure as your target
rate.
Front-Rear Linked:
“
Enabled
” links the front and rear
row units so that the same amount of pressure
increase/decrease set at the screen is applied to
front/rear row units. When “
Disabled
” - front/rear row
units are not linked. Two sets of buttons appear on the
screen that allow for adjustments of front and rear rates
independently.
Target Rate:
This is the desired down pressure on the
side depth wheels. The target rate to be entered is the
set rate (pounds) of the down force to determine how
much pressure is applied. The system monitors and
adjusts pressure to meet the defined rate set at this
screen.
Pressure displayed on screen and target pressure
both refer to the amount of weight carried by the side
depth gauge wheels, and not overall row unit down
pressure.
Inc/Dec: Sets the amount that the Target Rate is
changed with each key press during planting operations.
Figure 189
IntelliAg
®
Screen
36544
1
2
3
Figure 190
Float Mode ON/OFF Screens
2