NP2540
Appendix C - Accessory Installation
183
2019-04-12
417-459M
Revert Side Dress to Pre-Emergence
Revert Liquid
Possible Agricultural Chemical Hazard:
Wear chemical gloves while handling disconnected drop lines.
Hose may contain residual amounts of chemical fluids.
Consult the Material Safety Data Sheet (MSDS) for the
material most recently applied.
1. Disconnect drop line at coulter
2. If a single-coulter applicator, or three-coulter without
second boom, disconnect drop line at boom nozzle.
Replace nozzle with cap.
3. If a two-boom applicator, replace the half-rate orifice
plate in the side dress nozzle with the same plate
size used on the other rows. If using VeriFlow
nozzles, replace the half-rate nozzle with a full rate
nozzle.
4. Dismount side dress coulter. Frame extension may
be left in place.
5. If a three-coulter applicator, move coulter to rear
frame position from which it was removed. Re-install
all other removed rear coulters.
6. Restore hitch to center-line.
7. Note change in swath for rate calculations.
Revert Anhydrous
Suffocation, Blinding, Burning, Freezing, Disabling and
Disfigurement Hazards:
Do not perform this installation reversion without PPE or
without verifying system discharge. This process requires
opening a flow divider port to the atmosphere. This system
segment could contain liquid anhydrous ammonia (
NH
3
). It
would overwhelm your PPE
1. Discharge system (see “
2. Disconnect side dress delivery tubing at divider and
coulter. Leave tubing in place on frame.
3. Replace adapter at divider with plug.
4. Dismount coulter. Frame extension may be left in
place.
5. Restore hitch to center-line.
6. Note change in swath for rate setting.