Appendix C - Accessory Installation
179
2019-04-12
417-459M
Transfer Liquid Coulter
This applies only to kit 407-907A and three-coulter
configurations. For single-coulter configurations,
continue at “
” below.
20. Attach the hoist line to the loop at the top of the
quick-attach casting
.
21. At the casting bottom, remove and save two sets:
803
-
021C NUT HEX 5/8
-
11 PLT
804
-
022C WASHER LOCK SPRING 5/8 PLT
802
-
053C HHCS 5/8
-
11X1 3/4 GR5
804
-
095C WASHER FLAT 5/8 HARD ASTMF436
22. Use the hoist to remove the coulter assembly. Set
one assembly (with a straight shank) aside for use
as the side dress coulter.
23. Leave quick-attach mounts in place.
24. Move the selected coulter to the quick-attach coulter
mount on the side dress wing extension. It may be
necessary to rotate the coulter shank 180° in the
quick-attach weldment.
Continue at “
Close-Out Side Dress Liquid Coulter
below.
Install Liquid Coulter
This applies to kit 407-940A or 407-941A and single- or
2-coulter configurations. For 3-coulter configurations,
25. Select one each new:
149
-
584D COULTER CLAMP 6H X 4W
204
-
691K NP COULTER ASSY RH
two new:
806
-
016C U
-
BOLT 5/8
-
11 X 6 1/32 X 5 3/4
and four sets new:
804
-
022C WASHER LOCK SPRING 5/8 PLT
803
-
021C NUT HEX 5/8
-
11 PLT
26. Align the coulter shank
and clamp
at the
position marked at step 12 on page 177. Loosely
secure with U-bolts
, lock washers
and nuts
.
27. Adjust the coulter height to match the rest of the
applicator. Secure the clamp nuts.
Close-Out Side Dress Liquid Coulter
28. Connect the grease bank and fertilizer delivery
tubing previously on the left-most rear row.
29. Skip to “
30. Note change in swath for rate calculations.
Figure 110
Rear Coulter Mounts
34974
Possible Agricultural Chemical Hazard:
Wear chemical gloves while handling disconnected drop lines.
Hose may contain residual amounts of chemical fluids.
Consult the Material Safety Data Sheet (MSDS) for the
material most recently applied.
Figure 111
Install Single-Coulter Side Dress
34980