background image

 

 

Precautions

Page 4

The following precautions are designed to prevent accidents and injuries to 
yourself and others. Please ensure that you read, understand and follow these 
precautions thoroughly before using the product.

If the product appears to be damaged or there is obvious damage or malfunction, 
please contact GRAVEDA® Customer Service immediately at 

[email protected]

Never touch the hot plates or put your finger 
between them. There is a danger of burns and 
crushing!

Make sure that the device is always kept clean 
and free of dust.

Always connect the power plug to the appliance 
first and only then to the power outlet.

Before disconnecting the appliance from the 
power supply, make sure that the appliance is 
switched off.

The appliance is supplied with a power cord. DO 
NOT attempt to charge the unit with any other 
power cord/USB or otherwise without proper 
grounding.

Always turn the power off when you are not using 
the unit.

GRAVEDA®

       

GRASPRESSO®

Registered Trade Mark           Registered Trade Mark   

   

Summary of Contents for GRASPRESSO GP40-5

Page 1: ...GRAVEDA GRASPRESSO 5T Rosin Press Automatic pneumatic press with 5 Tons pressure Colophony press Model Number GP40 5 all rights reserved GRAVEDA GRASPRESSO Registered Trade Mark Registered Trade Mark ...

Page 2: ...duction Page 4 Precautions Page 5 Safety Instructions Page 6 Unpacking and assembly Page 7 Functions and components Page 8 Commissioning Page 9 Technical data sheet Table of contents GRAVEDA GRASPRESSO Registered Trade Mark Registered Trade Mark ...

Page 3: ...r damage to you or third parties caused by improper or incorrect or intentional misuse of the press The warranty does not cover accessories such as the glass plate glass insert or wear and tear of the battery The warranty does not apply if the damage to the article is due to forcible use maintenance Spare parts are available at cost price from GRAVEDA support at info graveda de Please pack the dev...

Page 4: ...ht by GRAVEDA The published contents brand names images and information provided are subject to German copyright and ancillary copyright law Any kind of reproduction editing distribution storage and any kind of use outside the limits of copyright law requires the prior written consent of the respective copyright holder Unauthorized copying saving of the information and brand names provided is not ...

Page 5: ...es or put your finger between them There is a danger of burns and crushing Make sure that the device is always kept clean and free of dust Always connect the power plug to the appliance first and only then to the power outlet Before disconnecting the appliance from the power supply make sure that the appliance is switched off The appliance is supplied with a power cord DO NOT attempt to charge the...

Page 6: ...or fire Always insert the USB charging cable completely DO NOT touch the power plug cable or device with wet hands If you need to unplug the power cord unplug it by the plug and not by the cord itself The cable could otherwise be damaged Do not scratch cut twist bend tie or place a heavy object on the cable DO NOT drop the power cord over the edge of the table where it could be accidentally bent o...

Page 7: ...efully With scissors or a knife 3 Remove the operating instructions and all other loose accessories 4 Remove the packaging materials and carefully take the device out of the carton 5 After unpacking the device check it for damage If there is any damage contact the GRAVEDA customer service immediately info graveda de 6 Make sure that all accessories are present 1 x GRAVEDA GRASPRESSO Rosin Press 5 ...

Page 8: ...inder LCD Controller Start Button Heating plates Cap of air regulator Air gauge Page 7 Air regulator Functions and components GRAVEDA GRASPRESSO Registered Trade Mark Registered Trade Mark Emergency button ...

Page 9: ...adjustment push the cap down when adjustment is complete We do not accept any liability for damage or injury to you or third parties caused by incorrect use or connection of the press to your existing air compressors We do not accept liability for damage to you or third parties caused by improper or incorrect or intentional misuse of the press 3 Set the temperature and time as desired 4 when the t...

Page 10: ...ime in seconds 5 After setting the time and temperature you can close the press with the lever On the control panel you will see a counter that shows the number of pressings so far 6 Press the start stop button The press will automatically close and start the process and count backwards based on the previously set time After the stopwatch has expired you can carefully open the press Press the Star...

Page 11: ...80 isopropyl alcohol by volume Wipe the plates with a dry clean cloth Repeat these steps to clean all associated components Place the prepared material in the middle of the lower plate Use the lever depending on the model to push the cylinder upwards until the desired pressure is reached Wait until the countdown has expired and the press starts beeping Press the Timer button again to turn off the ...

Page 12: ...g 37 kg Package size 51 x 33 5 x 62 cm Certification CE Technical data sheet GRAVEDA GRASPRESSO Registered Trade Mark Registered Trade Mark The crossed out dustbin symbol indicates that batteries rechargeable batteries button lines battery packs etc must not be disposed of with household waste Batteries are harmful to health and the environment Help protect the environment and dispose of batteries...

Reviews: