Checking NetCentral messages – PFC 500
23 July 2004
Profile XP Service Manual
59
RAID controller X that was
operating in non-mirrored
caching mode has detected a
non-recoverable memory fault
in the cache memory area.
Reboot the RAID system, then
the Profile. In Open SANs,
consult reboot procedures in the
Open SAN Instruction Manual,
or contact product support.
Replace the RAID controller if
needed.
A hardware failure occurred on
RAID controller X which
caused cache to be disabled.
System bandwidth will be
degraded.
Reboot the RAID system, then
the Profile. In Open SANs,
consult reboot procedures in the
Open SAN Instruction Manual,
or contact product support.
Replace the RAID controller if
needed.
The non-volatile memory on
RAID controller X was found to
be uninitialized. The controller
has initialized it to a default
state, and it will be functional
after a reboot.
Reboot the RAID system, then
the Profile. In Open SANs,
consult reboot procedures in the
Open SAN Instruction Manual,
or contact product support.
Replace the RAID controller if
needed.
RAID controller X is unable to
determine the correct logical
configuration of all units in the
system. Some units may become
unusable.
Reboot the RAID system, then
the Profile. In Open SANs,
consult reboot procedures in the
Open SAN Instruction Manual,
or contact product support.
Replace the RAID controller if
needed.
The redundant controller is no
longer responding to queries
from RAID controller X. The
system may be operation, but
Fibre Channel redundancy is
lost.
Reboot the RAID system, then
the Profile. In Open SANs,
consult reboot procedures in the
Open SAN Instruction Manual,
or contact product support.
Replace the RAID controller if
needed.
Fibre Channel port# 1 on the
Fibre Channel Disk board has
failed.
Restart the Profile, recheck for
messages, then run Profile
system diagnostics if needed.
Fibre Channel port# 2 on the
Fibre Channel Disk board has
failed.
Restart the Profile, recheck for
messages, then run Profile
system diagnostics if needed.
Both Fibre Channel ports on the
Fibre Channel Disk board have
failed.
Restart the Profile, recheck for
messages, then run Profile
system diagnostics if needed.
RAID storage messages
Possible cause
Corrective action
Summary of Contents for Profile XP PVS1000
Page 4: ...Product Support 4 Profile XP Service Manual 23 July 2004 ...
Page 28: ...Preface 28 Profile XP Service Manual 23 July 2004 ...
Page 32: ...Chapter 1 Characterizing the problem 32 Profile XP Service Manual 23 July 2004 ...
Page 50: ...Chapter 4 Troubleshooting audio problems 50 Profile XP Service Manual 23 July 2004 ...
Page 54: ...Chapter 5 Troubleshooting timecode problems 54 Profile XP Service Manual 23 July 2004 ...
Page 66: ...Chapter 6 Troubleshooting storage system problems 66 Profile XP Service Manual 23 July 2004 ...
Page 76: ...Chapter 7 Troubleshooting video network problems 76 Profile XP Service Manual 23 July 2004 ...
Page 82: ...Chapter 9 Troubleshooting channel control problems 82 Profile XP Service Manual 23 July 2004 ...
Page 88: ...Chapter 10 Routine maintenance 88 Profile XP Service Manual 23 July 2004 ...
Page 129: ...Viewing subsystem properties 23 July 2004 Profile XP Service Manual 129 ...
Page 150: ...Appendix A Diagnostic Tools 150 Profile XP Service Manual 23 July 2004 ...
Page 152: ...Appendix A Diagnostic Tools 152 Profile XP Service Manual 23 July 2004 ...
Page 156: ...Appendix A Diagnostic Tools 156 Profile XP Service Manual 23 July 2004 ...
Page 172: ...Index 172 Profile XP Service Manual 23 July 2004 ...