Replacing parts in a system with the redundancy option
23 July 2004
Profile XP Service Manual
105
Interpreting the DupliDisk III
control panel LEDs
The following describes how to interpret the control panel LEDs. The Primary and
Mirror LEDs display the status of the disk hardware on the Primary and Mirror
channels. The status LEDs for the Master and Slave display the RAID status on the
Master and Slave disk channels.
NOTE: In the Profile XP, the Slave Status LED is always lit and the Slave Primary
and Mirror LEDs are never lit because no slave drives are installed.
The following table explains the state of the LEDs for each drive (Primary and Mirror
The next table explains the state of the Status LEDs for the Master and Slave channels.
Operation of the DupliDisk III control panel buzzer
The following describes how to interpret the operation of the control panel buzzer.
LED color
Status
GREEN
Drives installed on the channel
ORANGE
(flashing)
Scanning the channel for drives
RED
Drive not installed
RED
(Flashing)
Error, the channel is marked as bad
ORANGE
Channel activity (Read/Write)
Master LED
Status
GREEN
Drives are in Mirror Mode and are Identical
GREEN
(Flashing)
Drives detected are in Mirror Mode, but may NOT be Identical
RED
Drives detected are NOT in Mirror Mode
RED
(Flashing)
Copy or compare operation is in progress
Orange
(Flashing)
Copy or compare operation is in progress
Buzzer operation
a
a.
Buzzer Off switch can be depressed to stop the beeping.
Status
Short beep during power up
Indicates successful DupliDisk II self test
Second beep
DupliDisk II is running in single mode
Continuous or intermittent beep
Drive failure
Summary of Contents for Profile XP PVS1000
Page 4: ...Product Support 4 Profile XP Service Manual 23 July 2004 ...
Page 28: ...Preface 28 Profile XP Service Manual 23 July 2004 ...
Page 32: ...Chapter 1 Characterizing the problem 32 Profile XP Service Manual 23 July 2004 ...
Page 50: ...Chapter 4 Troubleshooting audio problems 50 Profile XP Service Manual 23 July 2004 ...
Page 54: ...Chapter 5 Troubleshooting timecode problems 54 Profile XP Service Manual 23 July 2004 ...
Page 66: ...Chapter 6 Troubleshooting storage system problems 66 Profile XP Service Manual 23 July 2004 ...
Page 76: ...Chapter 7 Troubleshooting video network problems 76 Profile XP Service Manual 23 July 2004 ...
Page 82: ...Chapter 9 Troubleshooting channel control problems 82 Profile XP Service Manual 23 July 2004 ...
Page 88: ...Chapter 10 Routine maintenance 88 Profile XP Service Manual 23 July 2004 ...
Page 129: ...Viewing subsystem properties 23 July 2004 Profile XP Service Manual 129 ...
Page 150: ...Appendix A Diagnostic Tools 150 Profile XP Service Manual 23 July 2004 ...
Page 152: ...Appendix A Diagnostic Tools 152 Profile XP Service Manual 23 July 2004 ...
Page 156: ...Appendix A Diagnostic Tools 156 Profile XP Service Manual 23 July 2004 ...
Page 172: ...Index 172 Profile XP Service Manual 23 July 2004 ...