2-41
Installation Reference
Switch Reference
Table 2-6 lists potential settings and effects for switches used to
configure the Performer. The switches are located on the VAA
Board of the Performer switcher.
The table shows default settings in bold italic print. Address and
Starting Level default values are both zero (0). In the table, O = an
open
or
off
switch segment; C = a
closed
or
ON
switch segment.
For Switch 5, R = right direction; L = left direction.
Table 2-6.
Switch Reference, S1, 2, and 3 in Performer Switcher
Effect
Switch
Segments
1
2
3
4
5
6
7
8
7 Data Bits
S3
C
Selectable for ASCII and Model 200
protocols only. Other protocols are
always 8 data bits.
8 Data Bits
S3
O
300 Baud
S3
O
O
O
`
600 Baud
S3
O
O
C
1200 Baud
S3
O
C
O
2400 Baud
S3
O
C
C
4800 Baud
S3
C
O
O
9600 Baud
S3
C
O
C
19.2K Baud
S3
C
C
O
38.4K Baud
S3
C
C
C
76.8K Baud
S3
O
O
O
No Parity
S3
O
O
Even Parity
S3
O
C
Odd Parity
S3
C
O
VI Internal,
send external
S2
O
C
VI Internal,
don’t send
external
S2
O
O
VI S2
C
0
* 1. Address values are cumulative and are added into the total when the switch is in the
Closed (ON) position. In default 20-TEN compatible protocol, S1 is a source, destina-
tion, level offset determinant (see pages 2 - 54, 55, 56). Default address offset is 000.