Destination of Control (10BPS and MBCP panels)
BPS Panels control a single destination. This destination is
assigned by a switch on the BPS rear connector channel. The
switch is illustrated below. If a segment is down on the side
closest to the silkscreened 0, it adds no value to the destination
total. If a segment is down on the side closest to the
silkscreened number from 1 to 64, it adds that value to the
destination total. The selected destination will remain the
destination of control for BPS Panels.
MBCP panels allow the destination of control to be changed
using front panel buttons. For the MBCP, the switch-selected
destination is the default destination at power up. See the
Operation
section for details.
OPEN
12
34
5
6
7
8
0
0
0
0
0
0
0
1
2
4
8
16
32
64
DEST
In this example, the panel
destination is 7.
1 + 2 + 4 = 7.
Dot indicates switch down on that side