106
Expanded NV8576-Plus
Connecting the NV8576-Plus Frames
Making Router Control System Connections
An NV8576-Plus router with EM0666 control cards (i.e.,
standard
router) the cross-connection
uses RJ-45 cables with terminators.
An NV8576-Plus router with EM0833 control cards (i.e.,
hybrid
router) the cross-connection uses
BNC cables
without
terminators.
For Routers with EM0666 Control Cards
1 Face the rear of the router frames. Locate the
RTR EXP
connectors (RJ-45).
Fig. 6-9: RJ-45 Control Connections
Connect
RTR EXP
on one frame to
RTR EXP
on the other frame. Place terminators in the unused
RJ-45 ports.
For Routers with EM0833 Control Cards
1 Face the rear of the router frames.
Fig. 6-10: BNC Control Connections
2 Using a 75
W
BNC cable, connect
RTR EXP IN
on frame 1 to
RTR EXP OUT
on frame 2.
3 Using a 75
W
BNC cable, connect
RTR EXP OUT
on frame 1 to
RTR EXP IN
on frame 2.
Because the cables are paired, you can use two cables for redundancy.
Expansion Connectors (RJ-45)
Note
Miranda provides the terminators (WC0084). They are small; be careful not to overlook them.
Expansion Connectors (BNC)
Summary of Contents for NV8500 Series
Page 1: ...NV8500 Series Hybrid Digital Video Audio Routers User s Guide UG0034 09 30 Oct 2014 ...
Page 8: ...viii ...
Page 16: ...xvi Table of Contents ...
Page 124: ...108 Expanded NV8576 Plus Connecting the NV8576 Plus Frames ...
Page 134: ...118 Alarms Making Alarm Connections ...
Page 150: ...134 Power Connecting to Power ...
Page 161: ...145 NV8500 Series User s Guide Network Page Time Page ...
Page 204: ...188 M3 Cards M3 Cable and Connectors ...
Page 216: ...200 Maintenance Obtaining Service ...
Page 228: ...212 IP Gateway Specifications ...
Page 236: ...220 Frame Expansion ...
Page 246: ......