JUPITER L-S and LCD Series Control Panel Instruction Manual
75
Serial Data Cables
Net-1 IP Settings
Figure 34. Net-1 IP Settings
1.
Enter a unique value in the
Ethernet IP
field. This IP address must be
within the same network as the CM-4000.
For example, if the CM-4000 address is 192.168.253.10, then the L-S or
LCD Panels address should be changed to reside in the 192.168.253.x
network (such as “192.168.253.101”).
2.
Enter 255.255.255.0 in the Subnet Mask field.
3.
Enter a unique value in the
Gateway
field. This number is similar to the
Ethernet IP, except the last set of numbers should be “1.”
If the L-S or LCD Panels and the CM-4000 are on separate networks, the
gateway connecting them must be specified.
Net-2 IP Settings:
Not used to configure the panel.
Network Mode Selection - Enable DHCP if Box Checked
You must have a DHCP server to use this option.
Figure 35. Enable DHCP Settings
Follow these steps if you wish to use DHCP:
1.
Select or place a check in, the
Net-1: Set DHCP Mode
check box to turn on
DHCP mode.
2.
Select or place a check in, the
Net-2: Set DHCP Mode
check box to turn on
DHCP mode.
3.
Enter the amount of time, in seconds, for the panel to try to connect to
the DHCP server before the connection will time out in the
DHCP Mode
time-out (sec)
field.
Summary of Contents for JUPITER CONTROL PANEL L32 -
Page 12: ...12 JUPITER L S and LCD Series Control Panel Instruction Manual Contents ...
Page 14: ...14 JUPITER L S and LCD Series Control Panel Instruction Manual Preface ...
Page 30: ...30 JUPITER L S and LCD Series Control Panel Instruction Manual Regulatory Notices ...
Page 156: ...156 JUPITER L S and LCD Series Control Panel Instruction Manual Section 7 LCD Introduction ...
Page 164: ...164 JUPITER L S and LCD Series Control Panel Instruction Manual Section 10 LCD Configuration ...
Page 206: ...206 JUPITER L S and LCD Series Control Panel Instruction Manual Glossary ...
Page 216: ...216 JUPITER L S and LCD Series Control Panel Instruction Manual Index ...