![GRASS VALLEY 8900NET - Instruction Manual Download Page 55](http://html.mh-extra.com/html/grass-valley/8900net/8900net_instruction-manual_2257783055.webp)
8900NET—Instruction Manual
55
Using the 8900NET GUI
Frame Power Supply Web Pages
The frame Power Supply 1 or Power Supply 2 status web pages provide:
•
Power Slot Status – pass/fail status of the supply and fan in the power
supply sled (see
•
A Frame Health Reports link is given to the Frame Health Reporting
web page (
) where a fault report in the power supply can be
enabled or disabled as an alarm to the Frame Alarm connector on the
rear of the frame.
•
An LED Reports link is given to the LED Reporting web page (
)
where the power supply status reporting to the PS1 and/or PS2 LED on
the front of the 8900NET module can be disabled if desired.
•
When an SNMP manager is installed on the 8900NET module, an
SNMP Trap Reports link will be present. This will link to the SNMP
Reporting web page (
) where power supply fault and removal
can be configured for reporting to the SNMP manager.
Figure 30. Power Supply Slot Status Page
Use
this
link
Summary of Contents for 8900NET -
Page 6: ...6 8900NET Instruction Manual Preface ...
Page 49: ...8900NET Instruction Manual 49 Using the 8900NET GUI Figure 25 LED Reporting Web Page ...
Page 51: ...8900NET Instruction Manual 51 Using the 8900NET GUI Figure 26 SNMP Reporting Web Page ...
Page 82: ...82 8900NET Instruction Manual Specifications ...