8900NET—Instruction Manual
29
Status Monitoring and Reporting
Module Health Bus status will report the following items on a media
module:
•
Internal module state (and state of submodule or options enabled)
including configuration errors (warning), internal faults, and normal
operation (Pass).
•
Signal input states including valid/present (pass), not present or
invalid (warning), not monitored, and not available (no signal inputs).
•
Reference input states including locked/valid (pass), not
locked/invalid (warning), and not monitored.
•
Signal output states with reporting functionality (reference output).
The Module Health Bus status is also reflected on the 8900NET module.
When one of the above conditions exists on a media module, the MOD LED
on the front of the 8900NET module (
and
) will light indicating that there is an error condition on the Module
Health bus.
The Module Health bus status is also reported on the Frame Status web
page as a Fault (when 3 or more modules are reporting an error condition)
and on the Frame Alarm Reporting web page. This status reporting can be
enabled or disabled using the
Internal Healthbus
control on the Frame Alarm
Reporting web page (
Frame Alarm Reporting Web Page
). Dis-
abling this reporting does not disable the actual Module Health Bus
reporting to the Frame Alarm, only status reporting.
The Module Health Bus may be completely disabled by:
•
Setting DIP switch S1, segment 5 to
Disabled
(
), or
•
Unchecking the Module Health Reporting selection on the Frame
Reporting web page (
) or the LED Reporting web page
).
Summary of Contents for 8900NET -
Page 6: ...6 8900NET Instruction Manual Preface ...
Page 49: ...8900NET Instruction Manual 49 Using the 8900NET GUI Figure 25 LED Reporting Web Page ...
Page 51: ...8900NET Instruction Manual 51 Using the 8900NET GUI Figure 26 SNMP Reporting Web Page ...
Page 82: ...82 8900NET Instruction Manual Specifications ...