3.6.2 IPU-M2000 to IPU-M2000 Sync-Link cabling
Using the 0.15m red Ethernet RJ45 cable, wire the 16 IPU-M2000s as follows:
Starting from IPU-M2000 #1 at the bottom of the rack, insert one side of a cable into port 6 and one side of
another cable into port 7.
Insert the other side of the cable from port 6 of IPU-M2000 #1 into port 2 of IPU-M2000 #2, and the other side
of the cable from port 7 of IPU-M2000 #1 into port 3 of IPU-M2000 #2.
Fig. 3.44: IPU-M2000 Sync-Link ports
Continue the cabling for all IPU-M2000s. When completed the top row (6,7) of the top-most IPU-M2000 (#16)
connectors should be connected to the bottom row (2,3) of the bottom-most IPU-M2000 (#1) connectors with
1m red Ethernet RJ45 cables.
shows the final IPU-M2000 in-rack Sync-Link cabling.
Fig. 3.45: Final IPU-M2000 in-rack Sync-Link cabling