1 General description and safety
Ventilation requirements with
EcoExchanger
450 m³/h
Heat emitted to room (total/sensi-
ble/latent)
5,8 kW / 2,1 kW / 3,6 kW
Heat emitted to room with EcoEx-
changer (total/sensible/latent)
4,9 kW / 2,1 kW / 2,8 kW
Drainage
Drain hose Ø 28 mm - 1,5 m
Drain capacity requirement
50 l / min.
Drain water temperature
65 °C
Maximum lift height drain pump
800 mm
Drain pump
40 W
DETERGENT & RINSE AID
Liquid detergent and rinse aid dosing dispenser with peristaltic pumps
are integrated into X2 Lean Wash Center®
Prepared for dosing installation.
NOTE
X2 Lean Wash Center® must be installed according to na-
tional regulations. X2 Lean Wash Center® is supplied with a
2 metres long electric cable to be connected to an ap-
proved supply disconnecting device on the wall. The supply
disconnecting device is not included in the delivery.
* Not in use simultaneously
** For specific data regarding delivered units, please see rating plate
*** Factory settings. The settings can be changed according to the local
standards.
**** Do not clean the machine with high-pressure water.
12
Rev. 2022-04