Page 10
Wiring Diagram for Pedestrian Gate Electric Lock Control
IPI-101
Ethernet
not used
not used
GND
GND
12VDC Input
485_B
485_A
GND
Unlock Input
Monitor Input
NC
NO
COM
Press to Exit Button
inside gate to unlock
Pedestrian gate con-
nected to Intercom
Electric Strike Lock
on Pedestrian Gate.
If Lock is monitored
this can be connected
to the Intercom so the
open or close state of
the gate can be seen
in the monitor
Magnetic Lock on
Pedestrian Gate.
If Lock is monitored
this can be connected
to the Intercom so the
open or close state of
the gate can be seen
in the monitor
Power Adaptor
12VDC or other
12VDC source
such as that
from a gate
motor
+
-
-
-
Magnetic Position
Sensor if used for
Gate in case there is
no other monitoring
device
Note: There can only be one of either a Magnetic Lock OR Electric Strike lock per Gate or Door Output. Monitor connec-
tion output may need to have NO and NC terminals swapped around depending on open/close status of the gate/door.
Gate
or Door
Output
Monitor
Output if
exists
Monitor
Output if
exists
NO
NC
NO
NC
NO
NC
NO
OR
+
+
+
+