Page 16
Section 2: Technical Data
1
9
10
11
12
13
14
15
16
3
5
8
6
2
7
8A
4
Table 2-11:
Slimline MonoWave indirect HP cylinder connections and controls
Item
Description
Connection Size
Item
Description
Connection size
1
DHW out
22mm compression
9
Pressure reducing valve - 3 bar
-
2
T&P valve connection
1/2” BSPF
10
Balanced cold supply connection
22mm compression
3
Secondary return tapping
22mm compression
11
Expansion relief valve - 6 bar
15mm compression
4
Heat pump return tapping
22mm compression
12
Temperature & Pressure relief
valve - 90°C / 7 bar
15mm compression
5
Dual thermostat pocket
-
13
Tundish
15/22mm compression
6
Cold water inlet
22mm compression
14
Discharge pipe (not supplied with
cylinder)
-
7
Heat pump flow tapping
22mm
compression
15
Mains water supply pipe (not
supplied with cylinder)
-
8
Immersion heater c/w control &
limit thermostat (factory fitted)
1 ¾” BSPF
16
Drain cock (supplied with cylinder)
-
8A
Immersion heater c/w control &
limit thermostat (factory fitted)
300 only
1 ¾” BSPF
Notes:
1. Pipework between items 11 and 12 not supplied with cylinder.
Figure 2-10:
Slimline MonoWave indirect HP cylinder