P a g e
|
25
HT813 Administration Guide
Version 1.0.1.2
New Viewer
Password
Configures viewer level password.
Case sensitive and max. Length of 25 characters
Confirm Viewer
Password
Re-enter the viewer password to confirm change viewer password on web GUI to avoid
typo or mistakes.
Web/SSH Access
Web Session
Timeout
Configure timer to logout web session during idle.
Default is 10 min. Range is 2-60 min.
Web Access
Attempt Limit
Configure attempt limit before lockout.
Default is 5. Range is 1-10.
Lockout time
interval
If login attempt failed 5 times, login would be locked out for the time length.
Default 15 mins. Range 1-15 min.
Web Access Mode
Allows users to choose the Web Access Mode between “HTTPS” and “HTTP”. If
“HTTPS” is selected, web UI will be accessed using HTTPS. Default is “HTTP”.
HTTP Web Port
Customizes HTTP port used to access the HT813 web UI. Default is
80
.
HTTPS Web Port
Customizes HTTPS port used to access the HT813 web UI. Default is
443
.
Disable SSH
Enables/disables the SSH access. Default is
No
(disabled).
SSH Port
Allows users to self-configure SSH Port number. By default, the port number is
22
.
Disable Telnet
Enables/disables the Telnet access. Default is
Yes
(disabled).
Telnet Port
Allows users to self-configure Telnet Port number. By default, the port number is
23
.
WAN Side
Web/SSH Access
Enables/Disables the Web and SSH access through the WAN port. The available
options are the following:
No:
WAN side access for the Web GUI and SSH is disabled.
Yes:
WAN side access for the Web GUI and SSH is enabled.
Auto:
WAN side access allowed for private IP; rejected for public IP.
Default setting is
Auto
.
White List for WAN
Side
Allows users to configure the white List for WAN Side to be used for remote
management.
Multiple IPs are supported and need to be separated by “space”.
Example: 192.168.5.222 192.168.5.223 192.168.7.0/24