BLOWER REMOVAL
This furnace has a blower sealing system, which is designed to be tight and rattle free. Refer
to the instructions and pictures below.
1) Shut off oil and power to furnace.
2) Remove the two (2) screws
securing the blower door (Figure
1).
3) Open
blower
compartment
(Figure 2).
4) Disconnect the wiring to the
blower motor.
5) Remove the screw securing the
blower side to the separating
panel (Figure 3).
6) Slide the blower toward you and
get the blower out of the furnace
(Figure 4).
Figure 3
Figure 4