SoundPals User's Guide
DFADE-2 • 43
DFADE-2 Troubleshooting
The table below lists DFADE-2 problems and solutions.
Problem
Procedure
No signal at
either AES
output.
•
Is power applied? Check power LED
and power supply.
No audio on
AES output.
•
Is the input a good AES signal?
Check
I/P ERR
LED.
•
Is the input providing valid audio?
Check the
I/P VALID
LED.
•
Is the input signal silent? Check for
audio on the input. (Use a DAC-20
and headphones.)
One or both
level controls
do not work.
•
Is the product in unity gain mode?
Check
UNITY GAIN
DIP switches.
•
Is the product in stereo mode? Check
STEREO
LED.
Level wanders
unpredictably
•
Make sure product is not in remote.
Check
REMOTE
LED. If returning to
“local” corrects the problem, make
sure that
all
control inputs are
correctly driven.
Right remote
fader does not
work
•
Is the product in stereo mode? Check
STEREO
LED.
•
Is product in remote control mode?
Check
REMOTE
LED.
Remote control
interface not
active.
•
Is product in remote control mode?
Check
REMOTE
LED.
•
Remove the remote connector. Using
a short wire connect pin 1 to pins 2, 5,
6 and 7 in turn. Repeat for pin 3. If
operation is correct, check remote
interface wiring.
NOTE
Please contact the GPS factory if the problem still
exists after completing the above procedures.