7. SPECIFICATION SHEET
Gr
af
UK
Lt
d
12
290
Inlet Level
(varies with tank size)
H-Inv +
H-Inv -
W
L
H-Tot
GRAF ONE2CLEAN WASTEWATER SYSTEM SUPPLIED WITHIN CARAT TANK
FLEXIBLE HOSES TO BRING AIR INTO THE TANK FOR SYSTEM OPERATION
INTEGRATED SAMPLING CHAMBER
CLEAR WATER AIR LIFTER
AIR DIFFUSERS IN BASE OF TANK
Hiblow
XP - air pump
for 3, 5, 7 PE
Hiblow
HP - air pump
for 9, 10, 14, 18 PE
532
494
142
210
319
319
400
Ground Level
INTERNAL SYSTEM CONTROL
PANEL WITH DISPLAY AND
OPERATIONAL BUTTONS TO
SUPPORT COMPRESSOR
(EPP) EXTERNAL HOUSING
ENCLOSURE FOR INTERNAL
SYSTEM CONTROL PANEL
TELESCOPIC LID, SUITABLE FOR
EITHER PEDESTRIAN OR VEHICLE
LOADING REQUIREMENTS
625
685
350
1035
140-340
DO NOT SCALE - IF IN DOUBT ASK
REV.
DESCRIPTION
GRAF ONE2CLEAN
DRAWN :
CHECKED :
DSt
-
DATE :
SCALE :
14.08.20
NTS@A3
REV.
P0
DESCRIPTION
BY
DATE
THIS DOCUMENT IS SUPPLIED IN STRICT CONFIDENCE AND MUST NOT
BE LENT, REPRODUCED OR DISCLOSED TO ANY THIRD PARTY WITHOUT
THE WRITTEN CONSENT OF GRAF UK LIMITED
GRAF UK Limited
Graf UK Limited | Regen House | Beaumont Road | Banbury | OX16 1RH
T: 01608 661500 F: 01295 211333
E: [email protected] www.grafuk.co.uk
P0
FOR GUIDANCE
DS
14.08.20
GRAF ONE2CLEAN SYSTEM OPTIONS:
3750 LITRE CARAT TANK - 5 PE TREATMENT
PLANT
4800 LITRE CARAT TANK - 7 PE TREATMENT
PLANT
6500 LITRE CARAT TANK - 9 PE TREATMENT
PLANT
SCOPE OF SUPPLY:
GRAF ONE2CLEAN WASTEWATER SYSTEM
SUPPLIED WITHIN CARAT TANK
AIR DIFFUSERS IN BASE OF TANK
CLEAR WATER AIR LIFTER
INTERGRATED SAMPLING CHAMBER
TELESCOPIC LID, SUITABLE FOR EITHER
PEDESTRIAN OR VEHICLE LOADING
REQUIREMENTS
FLEXIBLE HOSES TO BRING AIR INTO THE TANK
FOR SYSTEM OPERATION
INTERNAL SYSTEM CONTROL PANEL WITH
DISPLAY AND OPERATIONAL BUTTONS TO
SUPPORT COMPRESSOR
OPTIONAL:
(EPP) EXTERNAL HOUSING ENCLOSURE FOR
INTERNAL SYSTEM CONTROL PANEL