Prime
Prime
1. Follow
Pressure Relief Procedure, page 14
.
2. Lock gun trigger. Remove tip and tip guard from
gun.
3. Place suction tube in the material that will be
sprayed.
Note
Do not stretch hose tight let it hang to
assist fluid flow into the pump.
4. Turn regulator adjustment knob (G)
counterclockwise until it stops, and gauge
(E) reads zero.
5. Open bleed type master valve (B).
6. Prime through drain valve if necessary.
Note
Usually 1K high viscosity materials.
NOTICE
Do not prime pump through drain/purge
valve using two component materials. Mixed
two-component materials will harden in valve
and result in clogging.
a. Place drain tube in a grounded waste pail.
Open drain/purge valve (J) slightly by rotating
counterclockwise.
Left: Xtreme Lower
Right: Dura-Flo
Lower
334645B
17