Prime
b. Start the pump by rotating the air regulator
adjustment knob (G) clockwise until pump
begins to move.
7. Prime hose and gun:
a. Disengage gun trigger lock. Hold the gun
against a grounded metal pail.
b. Trigger gun, slowly open regulator
adjustment knob (G) until pump beings to
cycle and a steady stream comes from gun.
Trigger gun for 10-15 seconds.
Note
If using an AA gun, increase air
pressure by turning gun regulator
clockwise.
c. Engage trigger lock.
8. The equipment is now ready to spray; go to
Spray, page 19
.
18
334645B