background image

Related Manuals

Related

Related

Related Manuals

Manuals

Manuals

Component Manuals in English:

Manual

Manual

Manual

Description

Description

Description

306287

Elevators and pump supports

308118

SST feed pumps, 5:1 and 10:1 ratio

307044

CS feed pump, 5:1 ratio

308738

CS feed pump, 10:1 ratio

307043

Monark

®

air motors

306982

President

®

air motors

Model

Model

Model Information

Information

Information

For maximum air and fluid working pressures and agency approvals of package components, see appropriate
component manual.

Model

Model

Model 25A598

25A598

25A598

Xtreme-Duty Agitator

II 1/2 G c IIC T4

ITS 16 ATEX 100984

0°C≤Ta≤50°C

List

List

List of

of

of Packages

Packages

Packages

Package

Package

Package

Agitator

Agitator

Agitator

Mounting

Mounting

Mounting

Support

Support

Support

Feed

Feed

Feed Pump

Pump

Pump

Approvals

Approvals

Approvals

25A599

25A599

25A599

AGITATOR ON DRUM

COVER

Xtreme-Duty Agitator

25A598

Drum cover with

recirculation kit

Handles on

drum cover

– – – – –

25A600

25A600

25A600

AGITATOR WITH

ELEVATOR

Xtreme-Duty Agitator

25A598

Drum cover with

recirculation kit

Elevator

with support

attachments

– – – – –

25A601

25A601

25A601

AGITATOR WITH

ELEVATOR AND FEED

Xtreme-Duty Agitator

25A598

Drum cover

with feed and

recirculation kit

Elevator

with support

attachments

5:1 CS Monark

25A602

25A602

25A602

AGITATOR WITH

ELEVATOR AND FEED

Xtreme-Duty Agitator

25A598

Drum cover

with feed and

recirculation kit

Elevator

with support

attachments

5:1 SST

Monark

25A603

25A603

25A603

AGITATOR WITH

ELEVATOR AND FEED

Xtreme-Duty Agitator

25A598

Drum cover

with feed and

recirculation kit

Elevator

with support

attachments

10:1 CS

President

25A604

25A604

25A604

AGITATOR WITH

ELEVATOR AND FEED

Xtreme-Duty Agitator

25A598

Drum cover

with feed and

recirculation kit

Elevator

with support

attachments

10:1 SST

President

3A4032B

3

Summary of Contents for Xtreme-Duty Agitator

Page 1: ...n gallon 200 200 200 liter liter liter open open open headed headed headed drums drums drums For For For professional professional professional use use use only only only Important Important Important...

Page 2: ...Operation 13 Pressure Relief Procedure 13 Setup 13 Using the Elevator included in some packages 14 Using the Agitator 14 Using the Feed Pump included in some packages 14 Service 15 Flushing the Agita...

Page 3: ...Approvals Approvals Approvals 25A599 25A599 25A599 AGITATOR ON DRUM COVER Xtreme Duty Agitator 25A598 Drum cover with recirculation kit Handles on drum cover 25A600 25A600 25A600 AGITATOR WITH ELEVATO...

Page 4: ...er or light switches on or off when flammable fumes are present Use only grounded hoses Hold gun firmly to side of grounded pail when triggering into pail Do not use pail liners unless they are anti s...

Page 5: ...uid in approved containers and dispose of it according to applicable guidelines PERSONAL PERSONAL PERSONAL PROTECTIVE PROTECTIVE PROTECTIVE EQUIPMENT EQUIPMENT EQUIPMENT Wear appropriate protective eq...

Page 6: ...Data Sheet SDS from distributor or retailer Turn off all equipment and follow the Pressure Pressure Pressure Relief Relief Relief Procedure Procedure Procedure when equipment is not in use Check equi...

Page 7: ...gitator air motor and gear reducer B Xtreme Duty agitator blade C Agitator shaft and coupler D Stainless steel drum cover F Recirculation tube G Ground wire with clamp H Feed pump strainer Key Key Key...

Page 8: ...and Gauge Items not supplied Grounding Grounding Grounding The equipment must be grounded to reduce the risk of static sparking Static sparking can cause fumes to ignite or explode Grounding provides...

Page 9: ...f injury from being crushed by equipment do not go under the elevator when it is raised Mount the drum cover as described in the Elevators and Pump Supports Manual 306287 The elevator must be in the d...

Page 10: ...below for the hole mounting pattern and minimum clearance required Attaching Attaching Attaching the the the Blades Blades Blades 1 Slide the agitator blade assembly B1 onto the shaft C1 positioned so...

Page 11: ...ef Ref Description Description Description AR Air Restrictor Elevator Speed EC Elevator Control Selector AS Agitator Shut Off Valve FP Feed Pump Shut Off Valve SA Supply Air Inlet LB Agitator Lubricat...

Page 12: ...em or other equipment A fluid drain valve is required to connect to the fluid outlet of the pump See the pump manual for details The drum cover also has two 1 in npt ports which have 1 1 2 in npt male...

Page 13: ...Setup Setup To reduce the risk of serious injury from moving parts and splashing fluid always shut off the agitator before you raise check or repair the agitator 1 Before turning on supply air make s...

Page 14: ...prevent air motor failure and possible damage to equipment always keep the air motor properly lubricated The Xtreme Duty Agitator is provided with an air line lubricator to aid in proper maintenance...

Page 15: ...ator Agitator Air Air Air Motor Motor Motor NOTICE NOTICE NOTICE To prevent air motor failure and possible damage to equipment always keep the air motor properly lubricated If an air line lubricator i...

Page 16: ...Notes Notes Notes Notes 16 3A4032B...

Page 17: ...539 REGULATOR air 1 16 113911 GAUGE 1 17 113630 FITTING 45 degree 1 8 in 1 18 155699 FITTING elbow 3 8 in 1 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 19 113333 VALVE b...

Page 18: ...H F F W W D D L LU U E E H H I IR R U UH H U UH H P P R R Y Y L LQ Q J J I IU UR R P P W WD D Q Q N N 2 2 0 0 3 3 2 2 1 1 1 1 7 7 5 5 8 8 3 3 7 7 8 8 5 5 R R Q Q R R W W H H F F H H H H G G S S V V L...

Page 19: ...9 COLLAR 1 921 101118 SCREW 2 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 922 111310 MOTOR air rotary 1 923 115841 FITTING elbow 1 924 129069 MUFFLER air exhaust 1 929 1...

Page 20: ...rk 5 1 sst 1 239326 PUMP President 10 1 cs 1 224348 PUMP President 10 1 sst 1 109 119992 FITTING nipple 3 4 in 1 110 248829 KIT regulator feed pump 1 111 256653 KIT fluid strainer 1 Ref Ref Ref Part P...

Page 21: ...28 L s Maximum Torque at Maximum Recommended Speed 1000 in lb 100 psi air pressure 113 N m 0 7 MPa 7 bar air pressure Stall Torque at Maximum Air Inlet Pressure 1120 in lb 127 N m Span Diameter of Agi...

Page 22: ...Y WARRANTY WARRANTY AND AND AND DISCLAIMS DISCLAIMS DISCLAIMS ALL ALL ALL IMPLIED IMPLIED IMPLIED WARRANTIES WARRANTIES WARRANTIES OF OF OF MERCHANTABILITY MERCHANTABILITY MERCHANTABILITY AND AND AND...

Reviews: