background image

Installation

Fluid

Fluid

Fluid Accessories

Accessories

Accessories

If using a feed pump, insert the pump into one of the
two 2 in. npt bungs in the drum cover. The pump may
be mounted on either side. Follow the installation
instructions in the pump manual.

Connect the air hose from the air control tee fitting
to the pump air control. A

A

A bleed-type

bleed-type

bleed-type air

air

air valve

valve

valve is

is

is

included

included

included in

in

in pump

pump

pump air

air

air control

control

control part

part

part 248829.

248829.

248829. If

If

If you

you

you are

are

are

not

not

not using

using

using this

this

this air

air

air control,

control,

control, a

a

a bleed-type

bleed-type

bleed-type air

air

air valve

valve

valve must

must

must

be

be

be installed.

installed.

installed.

A 3/4 in. feed hose is included with some packages.
Install the hose into the strainer on the outlet of the
pump and connect the other end to the inlet of the
proportioning system or other equipment.

A fluid drain valve is required to connect to the fluid
outlet of the pump. See the pump manual for details.

The drum cover also has two 1 in. npt ports (which
have 1–1/2 in. npt male threads underneath the
cover) which can be used for installing refill lines or
suction tubes.

A recirculation tube can be inserted into a strain relief
bushing installed in one of the two 2 in. bung plugs.
The bung plug has a 1/2 in. ID knockout feature
which keeps the bung sealed if a recirculation tube
is not used.

To install a recirculation tube, remove the strain relief
bushing from the bung plug and place a tube, punch
or other item against the knockout and strike with a
hammer. Make sure that any plastic is cleared from
the underside of the plug.

Once the knockout is removed, reinstall the strain
relief bushing and insert the recirculation tube.
Tighten the bushing against the tube to seal and hold
in place.

Ref.

Ref.

Ref.

Description

Description

Description

BP

Bung Plug

KN

Knockout

PA

Pump Air Controls

RT

Recirculation Tube

Ref.

Ref.

Ref.

Description

Description

Description

BS

Bushing

PA

Pump Air Hose

BP

Bung Plug

RP

Refill Port

12

3A4032B

Summary of Contents for Xtreme-Duty Agitator

Page 1: ...n gallon 200 200 200 liter liter liter open open open headed headed headed drums drums drums For For For professional professional professional use use use only only only Important Important Important...

Page 2: ...Operation 13 Pressure Relief Procedure 13 Setup 13 Using the Elevator included in some packages 14 Using the Agitator 14 Using the Feed Pump included in some packages 14 Service 15 Flushing the Agita...

Page 3: ...Approvals Approvals Approvals 25A599 25A599 25A599 AGITATOR ON DRUM COVER Xtreme Duty Agitator 25A598 Drum cover with recirculation kit Handles on drum cover 25A600 25A600 25A600 AGITATOR WITH ELEVATO...

Page 4: ...er or light switches on or off when flammable fumes are present Use only grounded hoses Hold gun firmly to side of grounded pail when triggering into pail Do not use pail liners unless they are anti s...

Page 5: ...uid in approved containers and dispose of it according to applicable guidelines PERSONAL PERSONAL PERSONAL PROTECTIVE PROTECTIVE PROTECTIVE EQUIPMENT EQUIPMENT EQUIPMENT Wear appropriate protective eq...

Page 6: ...Data Sheet SDS from distributor or retailer Turn off all equipment and follow the Pressure Pressure Pressure Relief Relief Relief Procedure Procedure Procedure when equipment is not in use Check equi...

Page 7: ...gitator air motor and gear reducer B Xtreme Duty agitator blade C Agitator shaft and coupler D Stainless steel drum cover F Recirculation tube G Ground wire with clamp H Feed pump strainer Key Key Key...

Page 8: ...and Gauge Items not supplied Grounding Grounding Grounding The equipment must be grounded to reduce the risk of static sparking Static sparking can cause fumes to ignite or explode Grounding provides...

Page 9: ...f injury from being crushed by equipment do not go under the elevator when it is raised Mount the drum cover as described in the Elevators and Pump Supports Manual 306287 The elevator must be in the d...

Page 10: ...below for the hole mounting pattern and minimum clearance required Attaching Attaching Attaching the the the Blades Blades Blades 1 Slide the agitator blade assembly B1 onto the shaft C1 positioned so...

Page 11: ...ef Ref Description Description Description AR Air Restrictor Elevator Speed EC Elevator Control Selector AS Agitator Shut Off Valve FP Feed Pump Shut Off Valve SA Supply Air Inlet LB Agitator Lubricat...

Page 12: ...em or other equipment A fluid drain valve is required to connect to the fluid outlet of the pump See the pump manual for details The drum cover also has two 1 in npt ports which have 1 1 2 in npt male...

Page 13: ...Setup Setup To reduce the risk of serious injury from moving parts and splashing fluid always shut off the agitator before you raise check or repair the agitator 1 Before turning on supply air make s...

Page 14: ...prevent air motor failure and possible damage to equipment always keep the air motor properly lubricated The Xtreme Duty Agitator is provided with an air line lubricator to aid in proper maintenance...

Page 15: ...ator Agitator Air Air Air Motor Motor Motor NOTICE NOTICE NOTICE To prevent air motor failure and possible damage to equipment always keep the air motor properly lubricated If an air line lubricator i...

Page 16: ...Notes Notes Notes Notes 16 3A4032B...

Page 17: ...539 REGULATOR air 1 16 113911 GAUGE 1 17 113630 FITTING 45 degree 1 8 in 1 18 155699 FITTING elbow 3 8 in 1 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 19 113333 VALVE b...

Page 18: ...H F F W W D D L LU U E E H H I IR R U UH H U UH H P P R R Y Y L LQ Q J J I IU UR R P P W WD D Q Q N N 2 2 0 0 3 3 2 2 1 1 1 1 7 7 5 5 8 8 3 3 7 7 8 8 5 5 R R Q Q R R W W H H F F H H H H G G S S V V L...

Page 19: ...9 COLLAR 1 921 101118 SCREW 2 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 922 111310 MOTOR air rotary 1 923 115841 FITTING elbow 1 924 129069 MUFFLER air exhaust 1 929 1...

Page 20: ...rk 5 1 sst 1 239326 PUMP President 10 1 cs 1 224348 PUMP President 10 1 sst 1 109 119992 FITTING nipple 3 4 in 1 110 248829 KIT regulator feed pump 1 111 256653 KIT fluid strainer 1 Ref Ref Ref Part P...

Page 21: ...28 L s Maximum Torque at Maximum Recommended Speed 1000 in lb 100 psi air pressure 113 N m 0 7 MPa 7 bar air pressure Stall Torque at Maximum Air Inlet Pressure 1120 in lb 127 N m Span Diameter of Agi...

Page 22: ...Y WARRANTY WARRANTY AND AND AND DISCLAIMS DISCLAIMS DISCLAIMS ALL ALL ALL IMPLIED IMPLIED IMPLIED WARRANTIES WARRANTIES WARRANTIES OF OF OF MERCHANTABILITY MERCHANTABILITY MERCHANTABILITY AND AND AND...

Reviews: