background image

Operation

Using

Using

Using the

the

the Elevator

Elevator

Elevator

(included

(included

(included in

in

in some

some

some packages)

packages)

packages)

Refer to the Elevators and Pump Supports Manual
306287 for detailed information about using the
elevator.

The elevator air control has three settings: RAISE,
OFF, and RUN.

• RAISE allows the elevator to be raised and

disables the agitator and feed pump air.

• OFF turns off all air pressure. If the elevator is

raised, OFF will lower the elevator.

• RUN enables the agitator and feed pump air.

A restrictor valve on the elevator air line slows the
elevator for safe operation.

Using

Using

Using the

the

the Agitator

Agitator

Agitator

Make sure that the agitator shut-off valve is in the
CLOSED position and the regulator is turned all the
way down.

If used, turn the elevator control to RUN.

Turn the agitator shut-off valve to the OPEN position.

Slowly open the regulator valve to increase agitator
speed until the desired speed is reached.

NOTE:

NOTE:

NOTE: Always maintain moderate agitator speed.
Excessive agitator speed may cause vibration,
foaming of fluid, and increased wear on parts.

NOTICE

NOTICE

NOTICE

To prevent air motor failure and possible damage
to equipment, always keep the air motor properly
lubricated.

The Xtreme-Duty Agitator is provided with an air
line lubricator to aid in proper maintenance. Fill
the lubricator with SAE #10 light oil and set the
lubricator feed rate at 1 drop of oil per minute
for high speed or continuous duty usage. Do
not overfeed oil or exhaust air may become
contaminated. To manually lubricate the air motor,
see

Lubricating the Agitator Air Motor, page 15

.

Using

Using

Using the

the

the Feed

Feed

Feed Pump

Pump

Pump

(included

(included

(included in

in

in some

some

some packages)

packages)

packages)

Fluid under high pressure can be injected through
the skin and cause serous injury. To reduce the
risk of an injury from injection, splashing fluid, or
moving parts, follow the Pressure Relief Procedure
whenever you:

• are instructed to relieve the pressure,

• stop spraying,

• check or service any of the system equipment,

• or install or clean the spray tips.

Refer to the feed pump manual and component
manual for any dispense equipment used for specific
operation and pressure relief instructions.

Feed

Feed

Feed Pump

Pump

Pump Pressure

Pressure

Pressure Relief

Relief

Relief Procedure

Procedure

Procedure

For feed pump pressure relief information, refer to
the appropriate feed pump manual.

Related Manuals, page 3

.

14

3A4032B

Summary of Contents for Xtreme-Duty Agitator

Page 1: ...n gallon 200 200 200 liter liter liter open open open headed headed headed drums drums drums For For For professional professional professional use use use only only only Important Important Important...

Page 2: ...Operation 13 Pressure Relief Procedure 13 Setup 13 Using the Elevator included in some packages 14 Using the Agitator 14 Using the Feed Pump included in some packages 14 Service 15 Flushing the Agita...

Page 3: ...Approvals Approvals Approvals 25A599 25A599 25A599 AGITATOR ON DRUM COVER Xtreme Duty Agitator 25A598 Drum cover with recirculation kit Handles on drum cover 25A600 25A600 25A600 AGITATOR WITH ELEVATO...

Page 4: ...er or light switches on or off when flammable fumes are present Use only grounded hoses Hold gun firmly to side of grounded pail when triggering into pail Do not use pail liners unless they are anti s...

Page 5: ...uid in approved containers and dispose of it according to applicable guidelines PERSONAL PERSONAL PERSONAL PROTECTIVE PROTECTIVE PROTECTIVE EQUIPMENT EQUIPMENT EQUIPMENT Wear appropriate protective eq...

Page 6: ...Data Sheet SDS from distributor or retailer Turn off all equipment and follow the Pressure Pressure Pressure Relief Relief Relief Procedure Procedure Procedure when equipment is not in use Check equi...

Page 7: ...gitator air motor and gear reducer B Xtreme Duty agitator blade C Agitator shaft and coupler D Stainless steel drum cover F Recirculation tube G Ground wire with clamp H Feed pump strainer Key Key Key...

Page 8: ...and Gauge Items not supplied Grounding Grounding Grounding The equipment must be grounded to reduce the risk of static sparking Static sparking can cause fumes to ignite or explode Grounding provides...

Page 9: ...f injury from being crushed by equipment do not go under the elevator when it is raised Mount the drum cover as described in the Elevators and Pump Supports Manual 306287 The elevator must be in the d...

Page 10: ...below for the hole mounting pattern and minimum clearance required Attaching Attaching Attaching the the the Blades Blades Blades 1 Slide the agitator blade assembly B1 onto the shaft C1 positioned so...

Page 11: ...ef Ref Description Description Description AR Air Restrictor Elevator Speed EC Elevator Control Selector AS Agitator Shut Off Valve FP Feed Pump Shut Off Valve SA Supply Air Inlet LB Agitator Lubricat...

Page 12: ...em or other equipment A fluid drain valve is required to connect to the fluid outlet of the pump See the pump manual for details The drum cover also has two 1 in npt ports which have 1 1 2 in npt male...

Page 13: ...Setup Setup To reduce the risk of serious injury from moving parts and splashing fluid always shut off the agitator before you raise check or repair the agitator 1 Before turning on supply air make s...

Page 14: ...prevent air motor failure and possible damage to equipment always keep the air motor properly lubricated The Xtreme Duty Agitator is provided with an air line lubricator to aid in proper maintenance...

Page 15: ...ator Agitator Air Air Air Motor Motor Motor NOTICE NOTICE NOTICE To prevent air motor failure and possible damage to equipment always keep the air motor properly lubricated If an air line lubricator i...

Page 16: ...Notes Notes Notes Notes 16 3A4032B...

Page 17: ...539 REGULATOR air 1 16 113911 GAUGE 1 17 113630 FITTING 45 degree 1 8 in 1 18 155699 FITTING elbow 3 8 in 1 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 19 113333 VALVE b...

Page 18: ...H F F W W D D L LU U E E H H I IR R U UH H U UH H P P R R Y Y L LQ Q J J I IU UR R P P W WD D Q Q N N 2 2 0 0 3 3 2 2 1 1 1 1 7 7 5 5 8 8 3 3 7 7 8 8 5 5 R R Q Q R R W W H H F F H H H H G G S S V V L...

Page 19: ...9 COLLAR 1 921 101118 SCREW 2 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 922 111310 MOTOR air rotary 1 923 115841 FITTING elbow 1 924 129069 MUFFLER air exhaust 1 929 1...

Page 20: ...rk 5 1 sst 1 239326 PUMP President 10 1 cs 1 224348 PUMP President 10 1 sst 1 109 119992 FITTING nipple 3 4 in 1 110 248829 KIT regulator feed pump 1 111 256653 KIT fluid strainer 1 Ref Ref Ref Part P...

Page 21: ...28 L s Maximum Torque at Maximum Recommended Speed 1000 in lb 100 psi air pressure 113 N m 0 7 MPa 7 bar air pressure Stall Torque at Maximum Air Inlet Pressure 1120 in lb 127 N m Span Diameter of Agi...

Page 22: ...Y WARRANTY WARRANTY AND AND AND DISCLAIMS DISCLAIMS DISCLAIMS ALL ALL ALL IMPLIED IMPLIED IMPLIED WARRANTIES WARRANTIES WARRANTIES OF OF OF MERCHANTABILITY MERCHANTABILITY MERCHANTABILITY AND AND AND...

Reviews: