background image

Operation

Operation

Operation

Operation

Pressure

Pressure

Pressure Relief

Relief

Relief Procedure

Procedure

Procedure

Follow the Pressure Relief Procedure
whenever you see this symbol.

This equipment stays pressurized until
pressure is manually relieved. To help prevent
serious injury from pressurized fluid such as
splashing fluid and moving parts, follow the
Pressure Relief Procedure before cleaning,
checking, or servicing the equipment.

1. Close the agitator shut-off valve.

2. Shut off the air supply to any accessories

such as feed pumps or an elevator.

Setup

Setup

Setup

To reduce the risk of serious injury from
moving parts and splashing fluid, always shut
off the agitator before you raise, check, or
repair the agitator.

1. Before turning on supply air, make sure all

valves are in the CLOSED or OFF position.

a. For elevator packages, make sure that

the elevator control selector is in the OFF
position.

b. Make sure that the agitator shut-off

valve is CLOSED.

c. If using a feed pump, make sure that the

pump shut-off valve is CLOSED.

2. Turn on the air supply to the system.

FP

WWLL     EE

$$

55

(( &&

S A

// %%

55 **

$$ 66

O

FF

RUN

RAIS

E

NN

Ref.

Ref.

Ref.

Description

Description

Description

AR

Air Restrictor (Elevator Speed)

EC

Elevator Control Selector

AS

Agitator Shut Off Valve

FP

Feed Pump Shut Off Valve

SA

Supply Air Inlet

LB

Agitator Lubricator

RG

Agitator Regulator and Gauge

3A4032D

13

Summary of Contents for Xtreme-Duty 25A598

Page 1: ...allon gallon gallon 200 200 200 liter liter liter open open open headed headed headed drums drums drums For For For professional professional professional use use use only only only Important Importan...

Page 2: ...e 13 Setup 13 Using the Elevator included in some packages 14 Using the Agitator 14 Using the Feed Pump included in some packages 14 Maintenance 15 Agitator Fasteners 15 Agitator Blades 15 Air Motor M...

Page 3: ...Mounting Support Support Support Feed Feed Feed Pump Pump Pump Approvals Approvals Approvals 25A599 25A599 25A599 AGITATOR ON DRUM COVER Xtreme Duty Agitator 25A598 Drum cover with recirculation kit H...

Page 4: ...or unplug power cords or turn power or light switches on or off when flammable fumes are present Use only grounded hoses Hold gun firmly to side of grounded pail when triggering into pail Do not use...

Page 5: ...ZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin inhaled or swallowed Read Safety Data Sheet SDS to know the specific hazards of the fluids you are using...

Page 6: ...Data Sheet SDS from distributor or retailer Turn off all equipment and follow the Pressure Pressure Pressure Relief Relief Relief Procedure Procedure Procedure when equipment is not in use Check equi...

Page 7: ...gitator air motor and gear reducer B Xtreme Duty agitator blade C Agitator shaft and coupler D Stainless steel drum cover F Recirculation tube G Ground wire with clamp H Feed pump strainer Key Key Key...

Page 8: ...the ground wire G to the ground connector GC on the side of the agitator and or drum cover Connect the clamp end of the ground wire to a true earth ground For an additional ground wire and clamp order...

Page 9: ...f injury from being crushed by equipment do not go under the elevator when it is raised Mount the drum cover as described in the Elevators and Pump Supports Manual 306287 The elevator must be in the d...

Page 10: ...below for the hole mounting pattern and minimum clearance required Attaching Attaching Attaching the the the Blades Blades Blades 1 Slide the agitator blade assembly B1 onto the shaft C1 positioned so...

Page 11: ...RAISE NN Ref Ref Ref Description Description Description AR Air Restrictor Elevator Speed EC Elevator Control Selector AS Agitator Shut Off Valve FP Feed Pump Shut Off Valve SA Supply Air Inlet LB Agi...

Page 12: ...ther end to the inlet of the proportioning system or other equipment A fluid drain valve is required to connect to the fluid outlet of the pump See the pump manual for details The drum cover also has...

Page 13: ...the risk of serious injury from moving parts and splashing fluid always shut off the agitator before you raise check or repair the agitator 1 Before turning on supply air make sure all valves are in t...

Page 14: ...revent air motor failure and possible damage to equipment always keep the air motor properly lubricated The Xtreme Duty Agitator is provided with an air line lubricator to aid in proper maintenance Fi...

Page 15: ...n become electrostatically charged when stirred or blended Dried material could allow static buildup and interfere with grounding To prevent fire and explosion ground equipment and do not allow materi...

Page 16: ...ator Air Air Air Motor Motor Motor NOTICE NOTICE NOTICE Not lubricating the air motor will cause air motor failure Install air line lubricator and air line filter If an air line lubricator is not inst...

Page 17: ...in 1 18 155699 FITTING elbow 3 8 in 1 19 113333 VALVE ball vented 1 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 20 16F151 FITTING connector 1 21 17M563 BRACKET guard cou...

Page 18: ...9 FITTING elbow 3 8 in 1 19 113333 VALVE ball vented 1 20 16F151 FITTING connector 1 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 21 17M563 BRACKET guard coupling 1 22 15...

Page 19: ...lvent and paint fumes can ignite or explode Material can become electr ostatically char ged Use equipment only in well ventilated ar ea Eliminate all ignition sour ces Gr ound all equipment in work ar...

Page 20: ...16P923 COUPLER adapter 1 917 100828 COUPLING flexible 1 918 16T063 COLLAR mounting 1 919 116940 SCREW SHCS 5 16 18 2 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 920 181...

Page 21: ...ription 25A599 25A599 25A599 25A600 25A600 25A600 25A601 25A601 25A601 25A602 25A602 25A602 25A603 25A603 25A603 25A604 25A604 25A604 Qty Qty Qty 101 25A598 Xtreme Duty agitator X X X X X X 1 102 17J0...

Page 22: ...0 1 sst X 1 109 119922 FITTING nipple 3 4 in X X X X X 1 110 248829 KIT regulator feed pump X X X X X 1 111 256653 KIT fluid strainer X X X X X 1 112 217382 HOSE 3 4 in 10 ft X X X X X 1 113 128689 PL...

Page 23: ...mum Recommended Speed 1000 in lb 100 psi air pressure 113 N m 0 7 MPa 7 bar air pressure Stall Torque at Maximum Air Inlet Pressure 1120 in lb 127 N m Span Diameter of Agitator Blades 13 75 in 349 mm...

Page 24: ...Y WARRANTY WARRANTY AND AND AND DISCLAIMS DISCLAIMS DISCLAIMS ALL ALL ALL IMPLIED IMPLIED IMPLIED WARRANTIES WARRANTIES WARRANTIES OF OF OF MERCHANTABILITY MERCHANTABILITY MERCHANTABILITY AND AND AND...

Reviews: